EK280
Key for the status pointer Sp.O:
−
a.mm_0s:b.c
Examples
Sz.A...
0.mm_0s:1.1
0.mm_02:2.1
0.mm_01:2.1
1.mm_0s:1.1
1.mm_02:2.1
1.mm_01:2.1
c)
Set up pulse duration:
i
The pulse duration can be set individually in seconds for each output.
−
In the corresponding output menu press the key until "PerO1", "PerO2",
displayed.
−
Press the ENTER key. ⇒ The set value flashes.
−
Move the cursor with the arrow keys or to the digits and change these with the arrow keys or
to the desired cycle duration.
−
Press the ENTER key to confirm the set value. It is possible to abort the entry by pressing the ESC
key.
Application Manual
c = 0: Message comes, c = 1: Message comes or goes
b = 1: Instance status, b = 2: System or overall status
s = status number (1...9 for St.1 ... St.9
* mm = message number (1...16),
a = 0: a message mm, a = 1: Message group from message 1 to mm
Description
A report in a Status St.1 to St.9
A message in system status StSy
A report in overall status StSy
Message group in system status StSy
VbSt Operating volume disturbance quantity
Message group in overall status Stat
51
or.
is
"PerO3"
"PerO4"