If required (i.e. with the aid of the enSuite user list) two further addresses for a "Domain Name
System" can be entered in addresses 3:0794.0 and 3:0795.0. This is however not essential.
d) Setting time window for potential data retrievals
In the base configuration now displayed you can define time windows, during which data can be retrieved
cyclically from the EK280 via the modem. There are two available time windows, which operate on EK280
battery power only and for versions of the EK280 with power supply there are two more, which operate only
on mains voltage.
i
Make the battery power time windows only as long and frequent as absolutely necessary. Each
time window reduces the EK280's battery life.
The editable time windows are not directly accounted for in calculation of expected battery life of
the "Bat.R" EK280 batteries. Therefore the expected battery life is not updated, when the time
windows are changed. Past time windows and data transfers are however used in remaining
battery and service life calculation for the "BatRC".
The two battery-power time windows are set in the enSuite device window under:
-
Parameters > Interfaces> Connections > Connection 1
-
Parameters > Interfaces> Connections > Connection 2
The two mains voltage time windows are set under:
-
Parameters > Interfaces> Connections > Connection 3
-
Parameters > Interfaces> Connections > Connection 4
If you do not need a time window, you can deactivate it by setting the time window start and end to the same
value.
Press the
"Transfer changes to
7.1.5.2 Checking GSM field strength
 chapter
7.1.4.2 Checking GSM field strength
7.1.5.3 Retrieving data with enSuite
a) Opening the test time window for the following test retrievals with enSuite
i
The test time window only needs to be open if none of the time windows 1 to 4 are open.
If the communication link to the EK280 via the optical interface is not set up, it must be created.
( chapter
3.1 Setting up the communication link to the EK280 via optical
Select "Navigation" on the left-hand side of the enSuite window and then
the bottom of the navigation window.
In the top of the device window open the path "Parameters" > "Interfaces" by clicking on the relevant
plus signs, and then select
Click on the "0" value next to
enter a duration in minutes (i.e. 10), for the test time window for the test retrieval to remain open. For
a battery-operated EK280 please do not enter an excessively long duration, as this will adversely
affect the battery life.
Application Manual
device" icon at the top of the enSuite window.
(p. 63)
"internal
modem" (not the plus sign before).
"Test call acceptance
window" in the right-hand side of the window and
and
and
interface, p. 19)
"Parameterize
67
online" at