EK280
Press the ENTER key to confirm the value setting. Input can be canceled using the ESC key.
To accept the set value move the cursor to the value "Store".
Press the ENTER key. ⇒
Change the value to
Press the ENTER key to confirm the value setting. Input can be canceled using the ESC key.
For"Vm" "VmP"
i
If the administrator lock is open and the transfer of "VmP" for "Vm" is rejected with the
message --13--, this process has previously been carried out.
Further changes are possible when either the calibration lock or the administration lock is open,
after deleting the change information regarding setting "Vm" at the same value as the gas meter
( chapter 2.4.4.1).
The following values are shown on the same menu:
Display
TimeX
Vm_o
Vm_n
2.4.4.1 Delete change information for synchronization Vm with the gas meter
Change information for adapting "Vm" to the gas counter must be deleted while the calibration lock is open in
order to re-set the volume under metering period conditions when the administrator lock is open:
Open the calibration lock
Move the cursor to
Press the ENTER key. ⇒
Change the value to
Press the ENTER key to confirm the value setting. Input can be canceled using the ESC key.
"TimeX"
(time stamp of synchronization),
to default values.

2.4.5 Parameterizing the volume at base conditions

i
A one-time setting up of the volume counter while the administrator lock is open is possible from
software version 2.20 and higher.
The quantity converter EK280 offers the possibility of adjusting the standard volume counter once during
commissioning of the unit while the administrator lock is open. Setting the volume is always possible while
the calibration lock is open and can also be carried out directly via Standard Volume (tab
> "Standard Volume" >
"Vb".
Method (without opening the calibration lock):
Application Manual
"0"
flashes.
"1"
by pressing the  or  arrow keys.
is taken.
Description
Time when counter synchronization was carried out
"Old" operating volume counter value Vm
"New" operating volume counter value Vm
>
"Serv."
"Volume" > "Actual volume" > "Synchronization Vm > "Clear".
"0"
flashes.
"1"
by pressing the  or  arrow keys.
"Vm_o"
(Vm old value),
"Vm_n"
15
(Vm new value) are set
"Serv."
to
"Volume"