Honeywell EK280 Applications Manual page 165

Volume converter
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

EK280
Point-in-
time
connection
0 = Server (not to be used for point in time connections)
3 = DLMS (the connection to the target is a DLMS connection)
TypPr
4 = Modbus-Master (the connection to the target is a Modbus connection)
5 = IEC1107 (the connection to the target is a IEC-1107 connection)
6 = EIServer (the target is an EI server)
Cycle
Cycle of a regular point in time connection (e.g. hourly, daily, weekly, monthly)
CW1.S
Start of a point in time connection (e.g. daily at 6:00 AM, or another time)
0 = no conn. (connection is inactive)
1 = dest 1 or 2
Destn
(a connection to target 1 is being constructed or if a fault occurs, to target 2 instead)
2 = dest 1 and 2 (a connection to target 1 and target 2 is being constructed)
Reference to a number in the telephone book, the recipient of this telephone book entry
Dst1, 2
will be called by the EK280.
2 = terminal / ext. modem
Iface
3 = internal modem
Type of power supply as a condition for the connection
1 = always
SuplT
2 = battery
3 = ext. supply
StCon
current status of this connection
SDst1, 2
current status of communication with the target
The function for the point in time connection can be triggered at any time (e.g. for testing
TestC
purposes).
Use the enSuite program and change over to the sub-menu
Telephone
book
Recipient's telephone number
TelNo
If a GSM modem is in use, then this number will be called.
Server TCP/IP address
If a GPRS modem is in use then an attempt is made to reach this IP address, and
Serv.
if no IP address has been parameterized then alternatively an attempt is made to
call the telephone number.
Server port number
Port
If a GPRS modem is in use then an IP connection is started off via this port.
Name
Name of recipient
Application Manual
Meaning
"Telephone
Definition
book" >
"Receiver 1 –
10"
163

Advertisement

Table of Contents
loading