EK280
Message Status Name
11
St.1
12
StSy
13
StSy
13
St.1
13
St.2
13
St.3
13
St.4
13
St.9
13
St.10
14
St.1
14
St.3
14
St.4
15
StSy
16
StSy
16
St.1
16
St.2
16
St.3
16
St.4
16
St.5
16
St.6
16
St.7
Application Manual
Description, Procedure
Encoder err.
No volume at measurement conditions was recorded at the
connected encoder on input 1 for 20 seconds (with external power
supply) or for one measurement cycle +1 second (battery
powered).
CDL full
The certification data log is full. Changing the parameters marked
with "CDL" without a calibration lock is only possible if the content
of the certification data log has been deleted.
online
Data is currently being transmitted via an interface (modem,
optical interface or terminal interface).
If this message is displayed, the "o" will flash in the "Status" field of
the display.
I1 Warn.sig.
When an input is configured as an information input, if an active
signal is present on the relevant terminal (i.e., terminal DE2) this
I2 Warn.sig.
message is displayed.
I3 Warn.sig.
The input configuration can be adjusted using the
parameterization program enSuite.
I4 Warn.sig.
I5 Warn.sig.
I6 Warn.sig.
Cal.lock o.
The calibration lock is open.
In normal operating conditions, the calibration lock should be
closed to prevent unauthorized changes.
To close the calibration lock, please go to "Ctrl."
and enter the value "0".
Admin.lock
The administrator lock is open.
Cust.lock
The customer lock is open.
Bat. operat.
The EK280 is in battery mode.
This signal is primarily used to inform a remote data transmission
system that the batteries run down more quickly during long
periods of data transmission.
Dayl.Sav.Tim
The time displayed in volume corrector is daylight saving time.
The switchover mode can be changed using the parameterization
program enSuite.
Call Win.1
The specified call pickup time is active, i.e. the volume corrector
will accept data transmission calls.
Call Win.2
Call Win.3
Call Win.4
Call Win.5
Call Win.6
call time1