Honeywell EK280 Applications Manual page 104

Volume converter
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

EK280
b) Sending parameter file
Send the following parameter file to the EK280 ( chapter
EK280_xvx.. - EM260 & i-module Modem 144 (Analogmodem) (*)
i
By loading this parameter file, the transmission speed at the terminal interface of the EK280 is
reduced to 9600 bps, even though EK280 can normally communicate across this interface at
19200 bps. This is necessary, because during operation with EM260 versions of model year up
to 2009 inclusive, transmission speeds of up to 19200 bps may lead to problems!
For any further individual settings and tests required, press "Navigation" on the left-hand side and
then
"Parameterize
i
All the values listed in enSuite under "Parameter" can be found on the "Serv." display tab of the
EK280 under the same path.
c) Setting time window for potential data retrievals
i
Before the first opening of a time window, the EM260 must be connected to the EK280  chapter
7.3.1) and the parameters be set ( chapter 7.3.2.2)!
In the base configuration now displayed you can define time windows, during which data can be cyclically
retrieved from the EK280 via the modem. Time windows 5 and 6 are reserved for EK280 operation with an
EM260. Redundant time windows can be deactivated by setting the time window start and end to the same
value.
In the top of the device window open the path "Parameters" > "Interfaces" by clicking on the relevant
plus signs, and then select
For call window 5, set the start to "00:00" and the end to "23:59" and then select the "Transfer
changes to device" icon at the top of the enSuite window.
Switch on the mains power supply of the EM260 again. The plug symbol in the Main Menu of the
EK280 shows the external supply.
Wait for around a minute for the EK280 to detect the EM260.
7.3.2.2 Parameterization of the analog PSTN modem integrated into EM260
If the order for the EM260 stated that it was to be operated connected to an EK280, the parameterization of
the EM260 was already effected at the factory, so you may skip this section.
If this was not the case, you may parameterize the EM260 yourself later, on location. However, this means
that, with the EM260 housing open, 230 VAC supply voltage must be connected, and only duly authorized
personnel is permitted to do such work.
14
The "x" stands for the version of software on the device, e.g. "2v2".
The * asterisk represents the lower-case letter, used to identify the file version, i.e. "a"
Application Manual
online" at the bottom of the navigation window.
"Call time
windows".
3.6 Send parameter
file, p. 21):
14
102

Advertisement

Table of Contents
loading

Table of Contents