Fe260 With Internal Analog Modem (Pstn Modem) - Honeywell EK280 Applications Manual

Volume converter
Hide thumbs Also See for EK280:
Table of Contents

Advertisement

EK280

7.4.9 FE260 with internal analog modem (PSTN Modem)

Modem adapter board 73016717 V1.2
with a connected telephone cable
La
Lb
La2
Lb2
This interface card is used as an interface for an analog telephone line.
Prerequisites for process described below:
The FE260 is connected and configured as described in  chapter 7.4.1.
7.4.9.1 Parametrization of the EK280
i
For parameterization of the EK280 you need a connection cable for the optical interface as well
as the enSuite program. enSuite can be downloaded free of charge from the Honeywell website
in the "Software Downloads" section:
www.elster-instromet.com/en/software-downloads
e) Closing the time windows
In order that the parameterization works correctly the time windows 5 and 6 must be closed. To do this:
Connect a PC with enSuite installed to the EK280 optical interface using the connection cable.
Start enSuite and set up the communication link to the EK280.
( chapter
3.1 Setting up the communication link to the EK280 via optical
Select "Navigation" on the left-hand side and then
navigation window.
In the top of the device window open the path "Parameters" > "Interfaces" by clicking on the relevant
plus signs, and then select
In call windows 5 and 6 set start and end to the same value for each one and then select the
"Transfer changes to device" icon at the top of the enSuite window.
Then wait a minute, for any communications activity in progress on the EK280 to be safely stopped.
Application Manual
Fig. 14: INSYS Analog modem module in the FE260
"Call time
windows".
INSYS analog modem
module
interface, p. 19)
"Parameterize
online" at the bottom of the
139

Advertisement

Table of Contents
loading

Table of Contents