Alarm Control Panel CA62 Installation and Programming Manual WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. The information in this manual is a subject to change without notice!
Page 2
Guarantee During the guarantee period the manufacturer shall, at its sole discretion, replace or repair any defective product when it is returned to the factory. All parts replaced and/or repaired shall be covered for the remainder of the original guarantee, or for ninety (90) days, whichever period is longer.
2.11 Installing of VD60 voice dialer to CA62 Alarm Control Panel ..............15 2.12 Installing of AJAX LAN Module in CA62 Alarm Control Panel ............... 16 2.13 Connecting of UWE432 Universal Wireless Expander to CA62 Alarm Control Panel ......16 2.14 Powering up the CA62 Alarm Control Panel ..................17 2.14.1 Technical Trouble Indication .....................
The system is based on a modular principle. The programming of CA62 can be done by two types of keyboards (LED or LCD) or remotely via ProsTE software. The security control is managed by means of a keyboard or a proxi reader.
➢ Avoid any loops of connecting wires within the very box and in their passage over or under the printed- circuit boarding. ➢ Additional relays MUSt Not be placed in the CA62 Alarm control panel box as these may generate electromagnetic interference when switched.
Installation and Programming Manual - СА62 Alarm Control Panel 2.3 СА62 Alarm Control Panel Metal Box Figure 1. Situation of СА62 alarm panel in metal box. CA62 Control panel Figure 2. Side view and mounting of universal metal box.
Installation and Programming Manual - СА62 Alarm Control Panel 2.4 СА62 Alarm Control Panel Plastic Box Figure 3. Opening the CA62 plastic box and template for wall mounting. 1 - Central support opening (behind PCB) 5 - Main cable opening...
Installation and Programming Manual - СА62 Alarm Control Panel 2.5 CA62 Alarm Control Panel Inputs and outputs Figure 5. CA62 control panel inputs and outputs. Terminals description of СА62 control panel: • AC - Power supply from 17V / 17VA mains transformer ...
Use the supplied 1 kΩ resistors to balance the zones. The balancing resistors are installed on the last detector of the circuit. The zones, which shall not be used, are terminated with one 1 kΩ resistor at the terminals of the CA62 Control Panel, irrespective of the chosen type of zone balancing.
Page 10
* You can use also two R=510Ω (one R is connected to every fire detector), instead of one R=1k. b) Connecting of two fire detectors to a doubling zone. Figure 7. Connecting a fire detector to CA62 alarm control panel.
Installation and Programming Manual - СА62 Alarm Control Panel 2.7 Connecting of Peripheral Devices to СА62 Alarm Control Panel 2.7.1 Connecting LED and LCD Keyboards to CA62 Alarm Control Panel Two types of keyboards can be used to control and program the СА62 alarm panel: •...
Page 12
Jt jumper should be placed on the most distant one. the Jt jumper is set by default. The cable connecting the LED61 Keyboards to the CA62 Control Panel must be no longer than 250m and have a cross- section of no less than 0.25mm.
PR62 any attractive supplement to the security system. The PR62 can be connected to the terminals RED, GREEN, YELLOW and BLACK of the CA62 together with the mounted keyboards. Up to two proximity readers can be included within one security system. Programming the various addresses onto the readers will provide identification by the TAMPER of each of these.
Installation and Programming Manual - СА62 Alarm Control Panel Using of PGM1, PGM2 and PGM3 Programmable outputs The СА62 Alarm panel PGM1, PGM2 and PGM3 outputs have a programmable active level. This allows them to be used to transmit control signals towards external devices (e.g. a block siren input) or to directly control low-powered external devices (e.g.
- by zone or by event (see description of ADDRESS 6035). Turn off the power supply in order to connect the PCB of the voice telephone dialer to the EXPAND socket of the CA62 Control Panel (1). Fix the PCB onto the pre-mounted plastic spacers (2). The telephone line should be connected to terminals A and B of the СА62 Control Panel.
2.12 Installing of AJAX LAN Module in CA62 Alarm Control Panel AJAX Module is an additional accessory for built-in installation in CA62 or any other security or fire control system. It transmits the system status to Monitoring centre or to the User via Internet. The AJAX module enables easy monitoring and transmitting of alarm events occurring in the security system to existing Monitoring centre using standard monitor- ing software.
Follow the next installation procedure when power-up the CA62 system for the first time: ➢ Set the JPRG jumper (Figure 5) on CA62 control panel, in order to configure the control panel default pa- rameters (the factory settings).
- Lights off Keyboard programming Entering the system engineer code will initiate the CA62 Alarm System programming mode for the engineer param- eters. After restoring the default parameters (system RESET) the engineer code will remain 7777. When you enter the engineer programming menu the indication of the used keyboards will be as follows: - LeD Keyboards - the LEDs RDY (green), ARM (red), TRBL (yellow) and BPS (red) are blinking together.
Detailed working instructions for the ProsTE software program are provided in the built-in Help files. The connection between the local computer and the CA62 control panel is via a specialized module (the module is not included in the CA62 equipment and is sold as a separate product.) The details listed in this manual apply to all parameters for remote system programming.
Installation and Programming Manual - СА62 Alarm Control Panel 0. eNGINeeR PARAMeteRS AND CoMMoN SettINGS ADDReSS 0000 - CHANGING tHe eNGINeeR CoDe A new access code to the alarm station engineer parameters can be assigned at this address. Note: If the 6-digit long access code is set, the combination "00" automatically will be added at the end of all valid codes in the system (see also the description of ADDRESS 1001).
Page 21
The procedure for enabling/ disabling the trouble mask indication are the same for all types and mod- mask els CA62 keyboards. Example for disabling a trouble indication mask using LCD62 keyboard: 1. АС Loss Loss of 220 V mains supply.
Page 22
Installation and Programming Manual - СА62 Alarm Control Panel ADDReSS 0014 - 220 V AC PoWeR SUPPLY FAILURe INDICAtIoN Enabling / Disabling for the programming of time delay indication in case of 220 V AC power supply failure. The time delay is in the range 0 - 180 min and is set on address 0018. 220 V AC The parameter status can be changed with pressing of random button of the keyboard.
Page 23
Installation and Programming Manual - СА62 Alarm Control Panel In case of TAMPER event in the system: - The LED indication and the internal buzzer of the key- Indication SILeNt boards are activated; tamper - Output TAMPER type is activated (no alarm signal 1 2 3 4 5 6 ...
Page 24
Installation and Programming Manual - СА62 Alarm Control Panel • LED blinks / ( ) at LCD - expecting confirmation from central station 5: Wait "kiss-off" • active state / or (5)/ - transmitted data has been successfully received ...
Page 25
Default settings - NO ADDReSS 0099 - SoFtWARe ReVISIoN ReVIeW The Engineer can review the number of current software revision of the CA62 control panel at this address. The indication is hexadecimal. The software revision is displayed as 4-digit number. The Software numbers are displayed one by one as the engineer uses the arrow buttons to see them all.
Installation and Programming Manual - СА62 Alarm Control Panel USeR AND MANAGeR CoDeS PRoGRAMMING ADDReSS 1000 - DeFAULt CoNFIGURAtIoN SettING Setting of CA62 Alarm control panel supports 4 default parameter configurations. default con- Enter a number from 0 to 3 of a default configuration. figuration All the menus in this manual are described for the DEFAULT CONFIGURATION 0.
Page 27
Installation and Programming Manual - СА62 Alarm Control Panel All the ADDRESS for User code attributes from 2 to 20 are programmed in the same way as ADDRESS 1010: - ADDReSS 1020 - USER CODE 2 ATTRIBUTES - ADDReSS 1030 - USER CODE 3 ATTRIBUTES - ADDReSS 1090 - USER CODE 9 ATTRIBUTES - ADDReSS 1100 - USER CODE 10 ATTRIBUTES - ADDReSS 1190 - USER CODE 19 ATTRIBUTES...
Installation and Programming Manual - СА62 Alarm Control Panel PRoGRAMMING oF ZoNeS The zone parameters in the system are programmed at ADDReSSeS 2xxx. The parameters for every zone are pro- grammed separately, as every zone has to be attached to one or the both partitions in the system. ADDReSS 2000 - NUMBeR oF ACtIVAtIoNS PeR ZoNe FoR AUto BYPASS MoDe The number of activations (number of alarm cycles from 0 to 9) in one arm mode, which have to be AutoBypass...
Page 29
Installation and Programming Manual - СА62 Alarm Control Panel Follow zone An alarm zone which is active only when the site is armed. The zone operates Indication instantaneously and activates the programmable ALARM and SIREN type outputs, and the communicator. ...
Page 30
Installation and Programming Manual - СА62 Alarm Control Panel Indication 24-hour auxiliary type zone When this zone type is assigned, respectively a number of AUX attribute 9. Auxiliary should be programmed at ADDReSS 2xx4, where xx is the number of the zone.
Page 31
Installation and Programming Manual - СА62 Alarm Control Panel ADDReSS 2012 - ZoNe 1 AttRIBUteS 2 Parameters "ATTRIBUTES 2" for ZONE 1 are programmed at this address. More than one attribute can be assigned for the zone. Pressing a digital button with the respective number will activate a given attribute.
Page 32
Installation and Programming Manual - СА62 Alarm Control Panel ADDReSS 2014 - ZoNe 1 AttRIBUteS AUX At this address are assigned only parameters "ATTRIBUTES AUX" for Auxiliary type zone. Only one attribute AUX can be assigned at this address - a number from 00 to 11. With an assigned AUX attribute and alarm in the zone, a system status message will the generated in Zone 1 the memory LOG file, which can be programmed to PGM output.
Page 33
Installation and Programming Manual - СА62 Alarm Control Panel ADDReSS 2026 - tYPe oF BALANCING FoR ZoNe 2 The type of ZONE 2 balancing is selected at this address. Every consecutive pressing of a digital but- ton alternatively changes the type of balancing. Display indications are given in the tables below. type of The doubling zone type connection can be realized to ZONE 2 - see the Figure 6 c.
Page 34
Installation and Programming Manual - СА62 Alarm Control Panel ADDReSS 2050 ... 2056 - ZoNe 5 PRoGRAMMING The programming is the same as that at ADDReSS 2010 - 2015, as the type, attributes (parameters 1, 2 and 3, AUX) as the attachment of ZONE 5 are assigned. The doubling zone type connection can be realized to ZONE 5 - see the Figure 6 c.
Installation and Programming Manual - СА62 Alarm Control Panel 3. PGM AND SIReN oUtPUtS PRoGRAMMING ADDReSS 3010 - PGM1 AttRIBUteS 1 PRoGRAMMING The events "ATTRIBUTES 1", which activate the programmable output PGM 1, are programmed at this address. An arbitrary combination of events, which activate the programmable output, is allowed. The output is activated upon the occurrence of any of the programmed events and is restored when all programmed PGM 1 events are discarded.
Page 36
Installation and Programming Manual - СА62 Alarm Control Panel The output is activated, when there is an alarm event in the system. For all kinds alarm events the siren will activate for programmed bell time for the respective partition (at ADDReSS 4012 for Partition А and ADDReSS 4022 for Partition В) or until a valid user code is entered.
Page 37
Installation and Programming Manual - СА62 Alarm Control Panel AC LoSS The output is activated in case of trouble in the main power supply of the control panel (control panel Control PCB). Panel MainBoard The output is activated in case of activating of a ZONE with assigned Auxiliary type and AC LOSS at- tribute - for controlling of devices working together with the control panel, for example additional power AC LoSS supply devices.
Page 38
Installation and Programming Manual - СА62 Alarm Control Panel The output is activated when an already armed zone with assigned "VIDEO-ON-ARMED" attribute is violated. "VIDEO-ON-ARMED" means that there is a video surveillance recording in the secured area. This parameter is valid for the programmed on ADDRESS 3014 (PGM1 EXTENSION X1). When using the doubling zone connection of the detectors in the system, there is a relation between Video-on- the used zones - ZONE1 corresponds to ZONE7, ZONE2 corresponds to ZONE8 and so on up to...
Page 39
Installation and Programming Manual - СА62 Alarm Control Panel ADDReSS 3018 - PGM 1 DeVICe ID (Keyboards) At this address a number of a keyboard from 1 to 4 for PGM1 extension attribute 18 assigned to AD- PGM 1 DRESS 3013. Device ID To activate the parameter press the digit button with the corresponding number.
Installation and Programming Manual - СА62 Alarm Control Panel 4. PARtItIoNS PRoGRAMMING At ADDReSSeS 40хх are assigned the attributes of the А and В partitions in the system. Every partition can be armed and disarmed independently. ADDRESS 4010 - PROGRAMMING OF EXIT TIME FOR PARTITION А Exit time is assigned to Entry/Exit type zones attached to Partition A.
Page 41
Installation and Programming Manual - СА62 Alarm Control Panel ADDRESS 4016 - PROGRAMMING OF ATTRIBUTES FOR PARTITION А The attributes of Partition A are programmed at this address. Every attribute is activated with pressing of a digit button with a respective number (from 1 to 4). The chosen attribute is indicated with activated Attributes number of the pressed digit.
Installation and Programming Manual - СА62 Alarm Control Panel 6. PRoGRAMMING oF CoMMUNICAtIoN DeVICeS 6.1 General parameters At ADDRESSES 60хх are programmed common parameters of the connected to the system communication devices. Note: Delete the queue of events to be sent to Address 0023 by single pressing the 0 button before configuring com- municator parameters of the digital communicator.
Page 43
Installation and Programming Manual - СА62 Alarm Control Panel ADDReSS 6011 - eNteRING PRotoCoL 1 NUMBeR FoR tHe CoMMUNICAtoR Enter central station No. 1 protocol number from the attached table. Valid are the symbols from 1 to 2, where: Indication Button Protocol PRotoCoL 1...
Page 44
Note: Recording and listening of voice messages can be done only if a voice dialer VD60 is integrated gramming to the CA62 control panel (main PCB ). ADDReSS 6031 - eNteRING teLePHoNe NUMBeR 1 FoR tHe DIALeR A telephone number is assigned for communicating via voice dialer No. 1. The indication is hexadeci- mal.
Page 45
Installation and Programming Manual - СА62 Alarm Control Panel ADDReSS 6035 - GRoUPS oF MeSSAGeS FoR VoICe DIALeR tRANSMISSIoN Programming the groups of message to be transmitted by the voice dialer at this address. The possible VD60 group options are 0 and 1. The status of the parameter is changed with pressing a random digit number. messages At SUPPLEMENT E - Examples for voice messages, are shown an examples for voice messages for zones and events.
The Answering Machine function should be enabled in such cases. During initial income of a series of machine calls (rings), the CA62 temporizes the maximum number of calls, set at Address 6904. The automatic answering machine must be adjusted to a fewer number of rings. If within four minutes there is another series of incoming calls the CA62 shall answer the first one.
Installation and Programming Manual - СА62 Alarm Control Panel 7. PRoGRAMMING oF PeRIPHeRAL DeVICeS 7.1 Programming of Keyboards At ADDRESSES 70хх are programmed the parameters and the attributes for the connected to the system keyboards. Up to 4 keyboards can be connected in the system. AtteNtIoN: the keyboards models LeD61, LCD62 and LCD62B Do Not SUPPoRt SIMULtANeoUSLY oPeRAtIoN WItH tHe BotH PARtItIoNS A and B.
Page 48
Installation and Programming Manual - СА62 Alarm Control Panel ADDReSS 7011 - LeFt ARRoW BUttoN oF KeYBoARD 1 At this address the arming mode of the system with the "left arrow" button of the keyboard 1 is as- signed. "Left arrow" The digital buttons 1 to 6 are used for programming.
Installation and Programming Manual - СА62 Alarm Control Panel The arming of the partition(s) is with specifying the arming mode type: Full, Stay or Instant. Example: With assigning this parameter, the system arming will be as follows: 6. Arm * ARM or + 0 - Full Arming Mode Following...
SUPPLeMeNtS - СА62 Alarm Control Panel SUPPLEMENT В eXAMPLeS FoR SeCURItY APPLICAtIoN WItH CA62 For illustration of the default factory configurations here are shown some examples for organizing the security system. The symbols used in the examples below have the following meaning: MC - Magnetic contact;...
Page 63
SUPPLeMeNtS - СА62 Alarm Control Panel DeFAULt CoNFIGURAtIoN 2 PART A Office 3 Default codes: Office 4 • User 1 - 1111 Book- • Manager - 0000 Keeping • Engineer - 7777 Corridor Office 1 Office 2 ENTRANCE PART A Central Entrance А...
Page 64
SUPPLeMeNtS - СА62 Alarm Control Panel DeFAULt CoNFIGURAtIoN 3 PART A Office 3 Default codes: Office 4 Book- • User 1 - 1111 Keeping • Manager - 0000 • Engineer - 7777 Corridor A Office1 Office 2 ENTRANCE PARTS A+B Central entrance Office 5...
SUPPLeMeNtS - СА62 Alarm Control Panel SUPPLEMENT С - Additional Information Coding recordings in log events The LOG Memory file can be viewed at ADDRESS 0024 in the Engineer menu (with entered valid engineer code), at ADDRESS 300 in the Manager menu (with entered valid Manager code), and ADDRESS 1 in the User menu (with entered valid user code with rights to view the log file).
Page 66
SUPPLeMeNtS - СА62 Alarm Control Panel Program mode entry Program mode exit Entering ambush code by xx user Telephone line failure Recovery of faulty telephone line Unsuccessful communication Periodic test message communication Digital communicator manual test ...
SUPPLeMeNtS - СА62 Alarm Control Panel Table of protocol Contact ID transmitted codes from CA62 Code Description 100 - Medical alarm Medical alarm 110 - Fire alarm Fire alarm 120 - Panic alarm Panic alarm 121 - Ambush code Code entered under ambush...
SUPPLeMeNtS - СА62 Alarm Control Panel Table of protocol SIA transmitted codes from CA62 Code Description AC Restore Restore 220V power supply AC Loss No 220 V power supply Burglary alarm Alarm Burglary bypass Bypassing an Entry/Exit, Follow or Instant type zone...
SUPPLeMeNtS - СА62 Alarm Control Panel SUPPLEMENT D - Algorithms for Operation of ZONES with Key-Switch Type In the tables below is described the working algorithm for Key-Switch type zones, according to the programmed at AD- DRESS 2013 parameter - Pulse or Latch. The operation of the Partition(s) and the sounder(s) is described on the right side of the tables.
Page 71
SUPPLeMeNtS - СА62 Alarm Control Panel Algorithm for Key-Switch type zones operating, Pulse parameter set on, when the zone is attached to TWO Partitions operation at incoming impulse from the zone Attribute Partition A Partition B Partition A Partition B Disarm ARMing ARMing...
SUPPLeMeNtS - СА62 Alarm Control Panel SUPPLEMENT Е Algorithm for Recording and Listening of Voice Messages Recording of voice messages Listening the recorded messages Recording and listening of voice messages in the system is programed at ADDRESS 6030 at the Engineer Programming menu.
Page 73
SUPPLeMeNtS - СА62 Alarm Control Panel Examples for voice messages MeSSAGe BY ZoNe (at ADDReSS 6035 is set 0) Messag. event example message Alarm or tamper from Zone 1. “Alarm from Zone 1” or “Alarm in Entrance zone” Alarm or tamper from Zone 2. “Alarm from Zone 2”...
SUPPLeMeNtS - СА62 Alarm Control Panel Solving of Technical Problems During Powering up of CA62 In case of technical trouble - No 220 V power supply, to solve the problem do as follows: Turn off the main power supply;...