Teletek electronics BRAVO Installation And Operation Manual
Teletek electronics BRAVO Installation And Operation Manual

Teletek electronics BRAVO Installation And Operation Manual

Wireless alarm control system
Hide thumbs Also See for BRAVO:
Table of Contents

Advertisement

BRAVO – Wireless Alarm Control Panel
BRAVO
Wireless Alarm Control System
Installation and
Operation
Manual

Advertisement

Table of Contents
loading

Summary of Contents for Teletek electronics BRAVO

  • Page 1 BRAVO – Wireless Alarm Control Panel BRAVO Wireless Alarm Control System Installation and Operation Manual...
  • Page 2: Table Of Contents

    3.6. Mounting of BRAVO SR 200 ........10 3.7. Mounting of BRAVO SR300 ........11 - The BRAVO panel is designed according and with 3.8. Mounting of BRAVO FL ..........12 conformity to high standards for test and operation 3.9.
  • Page 3: General Information For The System

    GENERAL INFORMATION 1. General Information for the System Supported types of peripheral devices: BRAVO is a wireless alarm control panel suitable for installation in residential houses and small offices. The BRAVO PIR – Passive infrared detector system is very easy to control via key fobs or MobileTTE smartphone application*.
  • Page 4: Planning Your Wireless System

    BRAVO – Wireless Alarm Control Panel GENERAL INFORMATION 2. Planning Your Wireless System  The control panel should be installed approximately within the center of the protected premises. In order to achieve the best efficiency of your wireless system, prior to installation plan the location of the control panel and the wireless devices within the premises.
  • Page 5: Basic Steps For Installation

    BRAVO – Wireless Alarm Control Panel GENERAL INFORMATION 3. Basic Steps for Installation  The construction and the width of the walls between the premises also affect the radio signals transmitted between the devices and the control 3.1. Preparation for mounting panel.
  • Page 6: Mounting And Connection Of

    3.3. Mounting and connection of BRAVO EXT BRAVO INTR BRAVO INTR is a wireless alarm panel with built-in  Run the connector of the power adapter through the power supply unit, which is factory mounted to the main cable channel and lead it on the internal side of bottom of the box.
  • Page 7: Mounting Of Bravo Pir

    BRAVO – Wireless Alarm Control Panel INSTALLATION 3.4. Mounting of BRAVO PIR BRAVO PIR is a wireless passive infrared detector for detecting of movement. Technical Characteristics: 1 х 3 V/ 1500mAh, Battery CR123A type Battery life 3 years (max. without LED)
  • Page 8 BRAVO – Wireless Alarm Control Panel 4. Mount the PCB back onto the base by placing it first Mounting on a wall Mounting in a corner on the front clips. Place for mounting bracket 5. Enroll the detector to the panel configuration as follow the steps described at item 6.2 in “System...
  • Page 9: Mounting Of Bravo Mc

    BRAVO MC is a wireless magnetic contact detection of drill an additional hole for the cables. door or window opening. BRAVO MC has a wired zone input for connecting of wired magnetic contact. ATTENTION: Remove the plastic cover from the...
  • Page 10: Mounting Of Bravo Sr 200

    4. Mount the siren base as first fix the screw for the main installation hole, then lever the siren, and at the BRAVO SR 200 is a wireless electrodynamic siren for end fix the supporting screws on the both sides.
  • Page 11: Mounting Of Bravo Sr300

    BRAVO SR300 is a wireless piezo siren for outdoor end fix the supporting screws on the both sides. mounting. The siren is available in two variant according the type of the used batteries: BRAVO SR300 AKL and BRAVО SR300 LIT. Technical Specifications:...
  • Page 12: Mounting Of Bravo Fl

    2. Remove the base of BRAVO FL and prepare it for Description of the PCB elements mounting at the place of installation. 1 – Protection folio for the battery; it is removed directly before the enrolment of the detector to the panel.
  • Page 13: Mounting Of Bravo Fd

    BRAVO – Wireless Alarm Control Panel INSTALLATION 3.9. Mounting of BRAVO FD BRAVO FD is wireless combined fire alarm detector with optical-smoke and heat (rate-of-rise) parts. Mounting holes Technical Characteristics: 2 х 3 V/ 1500mAh, Battery CR123A type Battery life 3 years (max.
  • Page 14: Preparing Of Bravo Rc

    BRAVO – Wireless Alarm Control Panel INSTALLATION 3.10. Preparing of BRAVO RC Specialized LED indication of a key fob BRAVO RC is a key fob remote control for: - Arming and Disarming of BRAVO system; The button has different LED and sound signalization - Information for the system status;...
  • Page 15: Mounting Of Communication Modules

    Monitoring Module Functionality and control The BRAVO panel can operate with up to two - Sending of messages for communication modules at the same time, mounted to events to Users; Slot 1 and Slot 2 on the main PCB of the panel.
  • Page 16: Bravo Gprs Module

    Mount BRAVO GPRS module to Slot 1 or Slot 2 on the Mount BRAVO PSTN module to Slot 1 or Slot 2 on the main PCB.
  • Page 17: Bravo Pstn Vd Module

    Mount BRAVO PSTN VD module to Slot 1 or Slot 2 on Mount BRAVO MOUT module to Slot 1 or Slot 2 on the the panel’s PCB.
  • Page 18 “Sounder Group” the connected wired siren is shown as device in position 16*. * Note: The indication will be active directly after the connection of BRAVO MOUT module to the panel’s PCB and set MOUT operation mode. Siren PCB For correct operation of the siren it is obligatory to connect 2x680K resistors as shown on the connection diagram.
  • Page 19: Hardware Settings

    BRAVO – Wireless Alarm Control Panel HARDWARE SETTINGS 4. Hardware Settings 4.2. Type configurations of the zones The installer can choose between two basic 4.1. Dip-switches configurations for the zone types with setting the Use the dip-switches to set some additional settings position of dip-switch 5.
  • Page 20: Hardware Reset

    BRAVO – Wireless Alarm Control Panel HARDWARE SETTINGS 4.3. Hardware reset 4.4. Sound signalization from the panel After hardware reset of the panel all default settings are restored, the enrolled devices and the memory log Signalization Description events are deleted.
  • Page 21: Description Of The Front Panel

    Groups Troubles for the System LED Indication for Zones/ Devices Control Buttons BRAVO Panel – Front view, open cover. 5.1. Buttons System Status System Control Button Alarm Review Button Programming - Entry/ Exit for “Reviewing Alarm Events” - Entry/ Exit for “Device enrolment” mode –...
  • Page 22: Led Indication

    To the group can be enrolled up to 16 Mains power supply 230V lost devices from BRAVO PIR, MC, FD or FL The sound signalization for mains power type – only 1 detector to each zone. supply lost can be immediate or delayed for programmed time interval.
  • Page 23: Device Enrolment

    BRAVO – Wireless Alarm Control Panel SYSTEM CONFIGURATION 6. Device Enrolment 6.2. General steps for enrolling a detector  The enrolment is a process of adding peripheral devices Prepare the detector for enrolling – remove the cover to the system configuration.
  • Page 24: General Steps For Enrolling An Outdoor Sounder

    The LED indicator under the icon is lighting on and the position 1 is blinking: The BRAVO panel supports operation with one outdoor sounder, which can be enrolled to position 1.  Switch on the battery – the LED on the PCB is lighting on in sequence in red and green.
  • Page 25: Test Of Devices

    MANAGER key fob enrolled to the system of the communication between the control panel and the configuration. wireless devices (BRAVO PIR, MC, FL, FD, SR200, SR300). To perform a zone walk test enter in sequence: The radio test can be performed directly after the...
  • Page 26: Deleting Of Devices

    “Device enrolment” mode. bypass it from the panel! Note: If a wired siren is connected to the panel via BRAVO MOUT module it is shown as Tips & Tricks... enrolled device to position 16. The wired siren can be bypassed in the same way as the ...
  • Page 27: Programming Of Parameters With Proste Software

    ProsTE. Menu “1. General Settings” Select the “1. General Settings” menu – at the right side Run the program and select the BRAVO panel from the of the screen are available the following settings: list.
  • Page 28 Select “2. RC Button *” – in the right side of the screen are displayed fields for setting of every of the key fobs, as BRAVO RC 1 corresponds to the key fob enrolled to position 1 of the control panel, BRAVO RC 2 corresponds to position 2 and so on.
  • Page 29 - Panel SN – Serial number of the panel - PC ID – User access code for reading/ writing - Panel version – Software version of the panel parameters to the BRAVO panel; ID number of the - Compilation Date – Software date panel.
  • Page 30 Select the “6. Slots” menu. At the right side of the screen are displayed parameters for setting. ATTENTION: mounted communication modules to the BRAVO PCB must be enabled for operation via the ProsTE programming software or AjaxWEB!  Enable Slots (enabling the communication modules).
  • Page 31 BRAVO – Wireless Alarm Control Panel CONFIGURATION WITH ProsTE SOFTWARE BRAVO GPRS At the right side of the screen are available the following settings: GPRS Settings “1. General Settings” Select the “1. General Settings” submenu from main menu “1. GPRS”: ...
  • Page 32 BRAVO – Wireless Alarm Control Panel CONFIGURATION WITH ProsTE SOFTWARE BRAVO PSTN and PSTN VD events to the successfully sent to the programmed first recorded phone These are submenus for setting the parameters of the phone number, the rest of the connected to the panel PSTN communication modules.
  • Page 33 BRAVO – Wireless Alarm Control Panel CONFIGURATION WITH ProsTE SOFTWARE In the field for BRAVO PSTN VD parameters are On the right side of the screen are displayed the available and the following values for setting: following parameters:  VD Message Repetitions – Enter a number of attempts for transmitting messages via the voice dialer to the recorded telephone numbers.
  • Page 34 - Burglary ALARM Това е меню за настройка на функционалността на Restore - Burglary ALARM Restore модул за управление BRAVO MOUT. В зависимост - TAMPER (from a device or from the от настройката изходите на модула работят в два Tamper and control panel различни...
  • Page 35 Menu 6. “Zone Names” Writing of system configuration. In this menu the installer can enter specific names for all  Select the BRAVO panel and use the right mouse zones in panel. button to open a list with control options: By default the names of zones are set as Zone 1, Zone 2, etc.
  • Page 36: Default Parameters After Hardware Reset

    BRAVO – Wireless Alarm Control Panel CONFIGURATION WITH ProsTE SOFTWARE Reading the Log memory file 7.10. Default Parameters after Hardware Reset  Select the BRAVO panel and use the right mouse Remote control “*” button No func button to open a list with control options:...
  • Page 37: Arm And Disarm Management

    IMPORTANT: To arm/ disarm and to check the status special disarm code is set via ProsTE software! of your BRAVO panel via smart phone you should install the mobile application Mobile TTE, which is available for Use the arrow buttons to enter digits from 1 to 9, download and installation from here: and 10 for 0.
  • Page 38: Operation With The System

    BRAVO – Wireless Alarm Control Panel USER INSTRUCTIONS 9. Operation with the System 9.4. Reviewing of Bypassed Devices 9.1. Reviewing of Alarm events Button lights on permanently in yellow. Button lights on permanently in red. Press the button to review the bypassed devices. The zone number of the first bypassed device is blinking and Press the button to review the current alarm events.
  • Page 39: Replacing Batteries

     Switch off the “Battery” connector from the terminal.  Remove the cover of the battery. As option, the outdoor sounder BRAVO SR can be  Replace the battery with new. Run the cable with powered on with adapter 12VDC/1A. The prepared connector through the side opening of the cover.
  • Page 40: Object Cart

    BRAVO – Wireless Alarm Control Panel MAINTENANCE 11. Object Cart  Communication and management: The object card of the site should be filled in by the GPRS  installer after the installation and configuration via PSTN digital communicator  ProsTE software.
  • Page 41 Double Action Mode zone (the device is activated). For example: BRAVO This is a specialized operation mode in BRAVO PIR for PIR is activated from a movement; BRAVO MC minimization of the false alarms in the system. In double magnetic contact is open –...
  • Page 42 The manufacturer shall not accept any product, of which no prior notice has been received via the RAN form at: http://www.teletek- electronics.com/en/support/Service The setup and programming included in the technical documentation shall not be regarded as defects. Teletek Electronics bears no responsibility for the loss of programming information in the device being serviced. CONDITIONS FOR WAIVING THE GUARANTEE This guarantee shall apply to defects in products resulting only from improper materials or workmanship, related to its normal use.
  • Page 43 www.teletek-electronics.com Address: Bulgaria, Sofia 1407, 14А Srebarna Str. Tel.: +359 2 9694 800, Fax: +359 2 962 52 13 e-mail: info@teletek-electronics.bg 18020247, Rev A, 11/ 2015...

Table of Contents