Programming Of Peripheral Devices; Programming Of Keyboards - Teletek electronics CA62 Installation And Programming Manual

Alarm control panel
Table of Contents

Advertisement

7.1 Programming of Keyboards

At ADDRESSES 70хх are programmed the parameters and the attributes for the connected to the system keyboards.
Up to 4 keyboards can be connected in the system.
AtteNtIoN:
the keyboards models LeD61, LCD62 and LCD62B Do Not SUPPoRt SIMULtANeoUSLY oPeRAtIoN WItH
tHe BotH PARtItIoNS A and B.
Simultaneously operation with A and В partitions are supported from LED62, LED63VG SE, LCD63SE, LCD64
keyboards.
ADDReSS 7000 - CHeCKING tHe Set KeYBoARD ADDReSS
Keyboard
At this address the set with jumpers address of each keyboard can be checked.
address
The indication is hexadecimal.
ADDReSS 7010 - KeYBoARD 1 SettINGS
At this address the Keyboard 1 parameters are assigned.
The digital buttons 1 to 6 are used for programming. Pressing them each time will alternatively change
the status of the parameter - active / inactive. At the end of the procedure only those parameters, which
correspond to the desired settings, should remain activated on the display.
Note: If a keyboard is attached to neither of the partitions, it can not control the system - arming,
Keyboard 1
disarming, bypass and etc. The user can only enter the engineer menu and do some settings in the
Settings
system.
1. PARt A
The keyboard is attached to Partition А. The User can perform actions in Partition A*.
2. PARt B
The keyboard is attached to Partition В. The User can perform actions in Partition B**.
3. Chime
This is local setting for the keyboard. When the attribute is assigned
disable
the keyboard will not produce the "Chime" sound signal.
With this attribute is assigning the number of the keyboard zone - 1 or
4. Keypad
7. With set parameter the keyboard will be zone 7. See also the table
zone
on the right.
5. Silent
With this attribute is assigned, in case of sent PANIC alarm signal from
Panic
the keyboard, the siren will not sound.
6. Zone
With this attribute the engineer can disable or enable the keyboard
enable
zone.
Default settings - PART A, Zone Enable
* User with a personal code with rights to operate in Partition A. User code with rights to operate only with Partition B will
be rejected.
** User with a personal code with rights to operate in Partition B. User code with rights to operate only with Partition A will
be rejected.
Installation and Programming Manual - СА62 Alarm Control Panel

7. PRoGRAMMING oF PeRIPHeRAL DeVICeS

At the default settings the display will show:
LeD
     
LCD
(1) 2 3 4 5 (6)
Attribute
OFF
ON
Keypad
zone
ZONE 1
ZONE 7
Attribute
Disabled
Enabled
Attribute
Disabled
Enabled
47
Indication
LeD
LCD
3
(3)
Indication
LeD
LCD
4
(4)
Indication
LeD
LCD
5
(5)
Indication
LeD
LCD
6
(6)