Installation and Programming Manual - СА62 Alarm Control Panel
The output is activated when an already armed zone with assigned "VIDEO-ON-ARMED" attribute
is violated. "VIDEO-ON-ARMED" means that there is a video surveillance recording in the secured
area.
This parameter is valid for the programmed on ADDRESS 3014 (PGM1 EXTENSION X1).
16.
When using the doubling zone connection of the detectors in the system, there is a relation between
Video-on-
the used zones - ZONE1 corresponds to ZONE7, ZONE2 corresponds to ZONE8 and so on up to
Armed
ZONE6 which corresponds to ZONE12. In this case the number of corresponding zone (7 - 12) have
to be assigned to ADDRESS 3015 (PGM1 EXTENSION X2).
The output is restored automatically after 1 minute and does not depend on the entered user codes or
the Pulse/Latch programming.
The output is activated in case of opening (activating) of ZONES which numbers are assigned at AD-
17.
DRESSES 3хх4 or 3хх5.
Zone
The output is deactivated when the assigned ZONES at ADDRESSES 3хх4 and 3хх5 are restored,
Violation
and does not depend on the arming mode - the output operates and in the ARM and in the DISARM
mode.
The output is activated at:
• entering a code with any of the programmed at ADDRESSES 3016 and 3017 numbers by any of
the programmed at ADDRESS 3018 keyboards.
18.
• entering of AMBUSH CODE
Code Used
• approaching a proxi card to the proximity reader
Signaling
• programming of a selected user code
The output is restored automatically after 4-5 seconds and does not depend on the arming mode and
the Pulse/Latch programming.
19.
The output is activated when approaching a proximity card to a selected proximity reader.
Proximity
The output is restored after 2-3 seconds and does not depend on the Pulse/Latch programming. The
Card Used
output does not depend also on the assigned PARTITION attachment of the code and the proximity
Signaling
reader.
ADDReSS 3014 - PGM 1 eXteNSIoN X1
At this address, as additional PGM1 attributes, are programmed code numbers for extensions from 16
PGM 1
to 19 assigned at ADDRESS 3013.
extension
User code or zone numbers from 1 to 6 are assigned.
X1
To activate the parameter press the digit button with the corresponding number. The next pressing of
the same digit button will deactivate the parameter.
ADDReSS 3015 - PGM 1 eXteNSIoN X2
At this address, as additional PGM1 attributes, are programmed code numbers for extensions from 16
PGM 1
to 19 assigned at ADDRESS 3013.
extension
User code or zone numbers from 7 to 12 are assigned.
X2
To activate the parameter press the digit button with the corresponding number. The next pressing of
the same digit button will deactivate the parameter.
ADDReSS 3016 - PGM 1 eXteNSIoN X3
At this address, as additional PGM1 attributes, are programmed code numbers for extensions from 18
PGM 1
and 19 assigned at ADDRESS 3013.
extension
User code numbers from 13 to 18 are assigned.
X3
To activate the parameter press the digit button with the corresponding number. The next pressing of
the same digit button will deactivate the parameter.
ADDReSS 3017 - PGM 1 eXteNSIoN X4
At this address, as additional PGM1 attributes, are programmed code numbers for extensions from 18
and 19 assigned at ADDRESS 3013.
PGM 1
User code numbers from 19 to 20 are assigned.
extension
Manager code number from 1 to 3 and/or Chief manager code are assigned.
X4
To activate the parameter press the digit button with the corresponding number. The next pressing of
the same digit button will deactivate the parameter.