62
SUPPLeMeNtS - СА62 Alarm Control Panel
eXAMPLeS FoR SeCURItY APPLICAtIoN WItH CA62
For illustration of the default factory configurations here are shown some examples for organizing the security
system.
The symbols used in the examples below have the following meaning:
MC - Magnetic contact;
PIR - Motion PIR detector;
KBD - Control keyboard;
СА62 - Control panel;
Zone n - Zone number.
DeFAULt CoNFIGURAtIoN 1
Office 3
Office 1
PART A
General information for DEFAULT CONFIGURATION 1:
• Zones - 6
• 1 partition - А
• 1 keyboard (suitable models LED61, LED62, LCD62, LCD62B, LCD63)
Short programming table for DEFAULT CONFIGURATION 1:
Zone
type
Bypass
1
Entry/Exit
Disarm Enable
Bypass, Stay
2
Follow
Disarm Enable
Bypass, Stay
3
Instant
Disarm Enable
Bypass, Stay
4
Instant
Disarm Enable
Bypass, Stay
5
Panic
Disarm Enable
6
Tamper
Disarm Enable
SUPPLEMENT В
Office 4
Office 2
Attributes
Part
A
A
А
А
А
А
Book-
Keeping
Corridor
Central
entrance
Detectors
Room
Central
MC1
Entrance
PIR1, PIR2
Corridor
Office 1
PIR3, PIR4
Office 2
Office 3
PIR5, PIR6
Office 4
Book-
PIR7
keeping
TAMPER
from all of the
All rooms
detectors
Default codes:
• User 1 - 1111
• Manager - 0000
• Engineer - 7777
Partitions in the system:
- PART А
ENTRANCE PART A
Control
KBD1
KBD1
KBD1
KBD1
KBD1
KBD1