Installation and Programming Manual - СА62 Alarm Control Panel
ADDReSS 0014 - 220 V AC PoWeR SUPPLY FAILURe INDICAtIoN
Enabling / Disabling for the programming of time delay indication in case of 220 V AC power supply
failure. The time delay is in the range 0 - 180 min and is set on address 0018.
220 V AC
The parameter status can be changed with pressing of random button of the keyboard.
failure
* The time delay set is valid for soft. rev. 4.3 and higher. If the soft. rev. of your control panel is
4.2 or lower, "YES" parameter sets 30 min time delay for power supply failure indication.
Instant indication for 220 V AC power supply failure
No
displayed on keyboards and message transmission via
digital communicator.
enable time delay indication for 220 V AC power
supply failure displayed on keyboards and message
YeS
transmission via digital communicator.
The time delay is in the range 0 - 180 min and is set on
address 0018.
-
Default settings
NO
ADDReSS 0015 - teLePHoNe LINe FAILURe INDICAtIoN DeLAY
A delay of 0 to 99 minutes is set prior to indication of a telephone line failure (ММ). The indication has
Line fault
a hexadecimal expression - see SUPPLEMENT С.
delay
Two digits are entered. When a period is less than 10 minutes the first digit introduced must be 0.
-
Default settings
00
ADDReSS 0016 - BeLL oN teLePHoNe LINe FAULt IN ARM MoDe
Enabling/ Disabling of sound signalization for telephone line fault, when the system is in ARM mode -
Bell on tel.
SIREN output is activated for the bell time of the sirens. It is possible the signalization to be activated
Line Fault
separately only for PARTITION A, only for PARTITION B, or for both of them for the same time.
The parameter status can be changed with pressing of random button of the keyboard.
The sound signalization for telephone line fault in ARM
No
mode is disabled.
The sound signalization for telephone line fault in ARM
mode is enabled. In case of telephone line fault in Par-
tition A, Partition B, or in both of them the sound sig-
YeS
nalization is on if the system is in ARM mode.
In the example the Bell on Tel.Line Fault parameter
is enabled for both Partitions A and B.
-
Default settings
NO
ADDReSS 0017 - tAMPeR ALARM SIGNAL
Programming of audible TAMPER event (a zone TAMPER type or physical tamper-switch is open)
when the system is disarmed.
Programming this address will not affect the TAMPER signal when the system is in armed mode. Pro-
tAMPeR
gramming this address will affect the performance of the programmable outputs type SIREN, ALARM
Alarm sig-
and TAMPER; the LED and sound indication of the keyboards and the digital communicator when the
nal
system is disarmed.
Every pressing of a digital button alternatively changes the enabled / disabled status. The display in-
dication is shown in the table.
In case of TAMPER event in the system:
- The LED indication and the internal buzzer of the
AUDIBLe
keyboards are activated;
tamper
- An alarm signal activated (activation of outputs type
ALARM, SIREN and ТАМPER);
- An alarm message is send to monitoring station.