Teletek electronics BRAVO Installation And Operation Manual
Teletek electronics BRAVO Installation And Operation Manual

Teletek electronics BRAVO Installation And Operation Manual

Wireless alarm control system
Hide thumbs Also See for BRAVO:
Table of Contents

Advertisement

BRAVO – Wireless Alarm Control Panel
BRAVO
Wireless Alarm Control System
Installation and
Operation
Manual

Advertisement

Table of Contents
loading

Summary of Contents for Teletek electronics BRAVO

  • Page 1 BRAVO – Wireless Alarm Control Panel BRAVO Wireless Alarm Control System Installation and Operation Manual...
  • Page 2: Table Of Contents

    3.1. Preparation for mounting ..........5 technical characteristics but not approved from the 3.2. Mounting and connection of BRAVO EXT ....6 manufacturer. 3.3. Mounting and connection of BRAVO INTR ....6 3.4.
  • Page 3: General Information For The System

    Up to two communication modules (GPRS, PSTN, PSTN VD or MOUT/PGM) can be added to the system  BRAVO RC - Two-way control key fob, 4 buttons for programming via Ajax SP web interface or  BRAVO RC-41 - One-way control key fob, 4 buttons MobileTTE smartphone application.
  • Page 4: Planning Your Wireless System

    BRAVO – Wireless Alarm Control Panel GENERAL INFORMATION  The control panel should be installed approximately 2. Planning Your Wireless System within the center of the protected premises. In order to achieve the best efficiency of your wireless system, prior to installation plan the location of the control panel and the wireless devices within the premises.
  • Page 5: Basic Steps For Installation

    BRAVO – Wireless Alarm Control Panel GENERAL INFORMATION  The construction and the width of the walls between 3. Basic Steps for Installation the premises also affect the radio signals transmitted between the devices and the control ATTENTION: Unit must be protected by external panel.
  • Page 6: Mounting And Connection Of Bravo Ext

    BRAVO INTR  Run the connector of the power adapter through the BRAVO INTR is a wireless alarm panel with built-in power supply unit, which is factory mounted to the main cable channel and lead it on the internal side of bottom of the box.
  • Page 7: Mounting Of Bravo Pir

    BRAVO – Wireless Alarm Control Panel INSTALLATION 3.4. Mounting of BRAVO PIR BRAVO PIR is a wireless passive infrared detector for detecting of movement. Technical Characteristics: Certified GRADE 2, Class II 1 х 3 V/ 1500mAh Battery (type CR123A) Battery life 3 years (max.
  • Page 8 BRAVO – Wireless Alarm Control Panel INSTALLATION 4. Mount the PCB back into the base by placing it first ATTENTION: When the detector is installed on the front clips. on a mounting bracket, it is impossible to use the second tamper-switch for self-protection...
  • Page 9: Mounting Of Bravo Pir Ext Gjd

    IP65 * The dip-switch DSW 1 is set to OFF position (see item 4.1). Package contains: In the packing box of outdoor detector BRAVO PIR EXT GJD are included the following additional parts: - 1 pc drilling template - Wall plugs (3х31.75mm) and mounting screws (3х31.75mm)
  • Page 10 It is operation can be disabled from the panel – see item 4. Remove the protective folio of the batteries. BRAVO PIR EXT GJD is powered from 3 batteries – one on the 4.1.
  • Page 11: Mounting Of Bravo Curtain

    To enter the test mode, switch the dip-switch 4 on detector’s PCB in ON position. While in test mode, the detector will send signal to the Bravo panel every time it detects movement. In order to turn off the Test mode, turn dip-switch 4 OFF.
  • Page 12 BRAVO – Wireless Alarm Control Panel INSTALLATION Beam Coverage: Description of the PCB elements The elements of PCB of BRAVO Curtain are situated  onto its both sides. Side View Use the small plain screw driver from the kit to turn ON/OFF the dip-switches.
  • Page 13: Mounting Of Bravo Mc

    * The dip-switch DSW 1 is set to OFF position (see item 4.1). ** When a wired magnetic contact or a rolling shutter detector is connected to the BRAVO MC wired zone, the battery life is reduced if Description of the PCB elements the frequency of using is increased.
  • Page 14: Mounting Of Bravo Sr200

    In case a wired magnetic contact is connected to “Wire Zone” terminal, BRAVO MC will follow its activation and will alert the panel when the system is armed. Bravo MC will be activated only when the wired part gets triggered.
  • Page 15: Mounting Of Bravo Sr300

    BRAVO SR300 is a wireless piezo siren for outdoor the supporting screws on the both sides. mounting. The siren is available in two variant according the type of the used batteries: BRAVO SR300 AKL and BRAVО SR300 LIT. Technical Specifications:...
  • Page 16: Mounting Of Bravo Fl

    5. Enroll the siren to the panel as follow the steps described at item 6.5 in “System Configuration” section. 2. Remove the base of BRAVO FL and prepare it for Description of the PCB elements mounting at the place of installation.
  • Page 17: Mounting Of Bravo Fd

    3.11. Mounting of BRAVO FD the floor of the protected room, and the main body BRAVO FD is a wireless combined fire alarm detector above is at higher position – up to 2 meters. with optical-smoke and heat (rate-of-rise) parts.
  • Page 18: Bravo Key Fobs

    Mounting for different applications. holes 3.12.1 BRAVO RC BRAVO RC is a two-way communication key fob with following functionalities: - Arming and Disarming of BRAVO system; - Sending of additional commands to the panel, programmable via ProsTE software;...
  • Page 19: Bravo Rc-Xx

    (Info) has different LED and sound signalization when a control button is pressed: The BRAVO panel can operate with up to two communication modules at the same time, mounted to Slot 1 and Slot 2 on the main PCB of the panel.
  • Page 20: Bravo Tte Gprs Module

    GRADE_2, Class II, SP2 (SMS), SP5 (GPRS) certified. off the main and backup power supply. Mounting Mount BRAVO MOUT module to Slot 1 or Slot 2 on the 1. Remove the cover of the panel – see item 3.1. panel’s PCB.
  • Page 21 – ATTENTION: Install the transmitter unit at distance External power at least 5m from the BRAVO MOUT module to through the backup channel. supply unit guarantee the correct operation of the system!
  • Page 22: Bravo Pstn And Pstn Vd Modules

    PCB (on the back side of the module PCB). off the main and backup power supply. 2 - Mounting holes. Mount BRAVO PSTN (PSTN VD) module to Slot 1 or 3 - Terminals for connecting of telephone line and Slot 2 on the panel’s PCB.
  • Page 23: Hardware Settings

    BRAVO – Wireless Alarm Control Panel HARDWARE SETTINGS 4. Hardware Settings 4.2. Type configurations of the zones The installer can choose between two basic 4.1. Dip-switches configurations for the zone types with setting the Use the dip-switches to set some additional settings position of dip-switch 5.
  • Page 24: Hardware Reset

    BRAVO – Wireless Alarm Control Panel HARDWARE SETTINGS 4.3. Hardware reset 4.4. Sound signalization from the panel After hardware reset of the panel all default settings are restored, the enrolled devices and the memory log Signalization Description events are deleted.
  • Page 25: Description Of The Front Panel

    Groups Troubles for the System LED Indication for Zones/ Devices Control Buttons BRAVO Panel – Front view, open cover. 5.1. Buttons System Status System Control Button Alarm Review - Entry/ Exit for “Reviewing Alarm Events” Button Programming - Entry/ Exit for “Device enrolment” mode –...
  • Page 26: Led Indication

    To the group can be enrolled up to 16 bottom is broken. devices from BRAVO PIR, MC, FD or FL Mains power supply 230V lost type – only 1 detector to each zone.
  • Page 27: Device Enrolment

    LED(s) of the detector is lighting in sequence in red The minimum distance between the panel and and green. For BRAVO Curtain – connect the battery enrolled peripheral devices must be 1 meter (in to the connector on the PCB (back side).
  • Page 28: General Steps For Enrolling A One-Way Key Fob

    By default the button  After successful enrolment to the panel, write down and “B” of BRAVO RC-41 and the button of BRAVO the zone number on the sticker and place it on the RC-11 have no functionality. The installer can program inner side of the detector’s enclosure.
  • Page 29: Test Of Devices

    MANAGER key fob enrolled to the system communication between the control panel and the configuration. wireless devices (BRAVO PIR, MC, FL, FD, SR200, SR300, etc). To perform a zone walk test enter in in “Device enrolment” mode and then press 3 times the The radio test can be performed directly after the “Programming”...
  • Page 30: Deleting Of Devices

    “Device enrolment” mode. bypass it from the panel! Note: If a wired siren is connected to the panel via BRAVO MOUT module it is shown as Tips & Tricks... enrolled device to position 16. The wired siren can be bypassed in the same way as the ...
  • Page 31: Arm And Disarm Management

    IMPORTANT: To arm/ disarm and to check the status special disarm code is set via ProsTE software! of your BRAVO panel via smart phone or tablet you should install the mobile application MobileTTE, which Use the arrow buttons to enter digits from 1 to 9, is available for download and installation from here: and 10 for 0.
  • Page 32: Operation With The System

    It is Button lights on permanently in yellow. available only with BRAVO RC two-way remote control. The panel performs two short sound signals at every To increase the signal strength, press at the same 20 seconds.
  • Page 33: Pstn Communicator Test

    This is a functional test for correct operation of BRAVO This is a test for the LED indication of the panel for the PSTN or BRAVO PSTN VD mounted on Slot 1 or 2 of zones and events. the panel.
  • Page 34: Algorithm For Bravo Pstn Vd Module

    Panel via BRAVO PSTN VD Module The BRAVO systems with BRAVO PSTN VD communication module allows the Users to perform a remote controlling of panel. If within 40 seconds there is no action – pressed button, the system will automatically cut off the...
  • Page 35: Replacing Batteries

    CR123A 3V/ 1500mAh! IT IS OBLIGATORY TO REMOVE THE BATTERIES OF ALL DEVICES if the BRAVO system will not be in To replace the battery with new: use for a long time and the main and back-up power ...
  • Page 36: Object Cart

    BRAVO – Wireless Alarm Control Panel MAINTENANCE  11. Object Cart Type of the remote control: The object card of the site should be filled in by the Programmed buttons Number Type installer after the installation and configuration via ProsTE software.
  • Page 37 Double Action Mode zone (the device is activated). For example: BRAVO This is a specialized operation mode in BRAVO PIR for PIR is activated from a movement; BRAVO MC minimization of the false alarms in the system. In double magnetic contact is open –...
  • Page 38 The BRAVO EXT and BRAVO INTR control panels are designed according and with conformity to the European Union (EU) Low Voltage Directive (LVD) 2006/95/EC and Electro-Magnetic Compatibility (EMC) Directive 2004/108/EC. The CE mark is placed for indication that the BRAVO control panels comply with the requirement of EU for safety, health, environmental and customer protection.
  • Page 39 BRAVO – Wireless Alarm Control Panel NOTES...
  • Page 40 www.teletek-electronics.com Address: Bulgaria, Sofia 1407, 14А Srebarna Str. Tel.: +359 2 9694 800, Fax: +359 2 962 52 13 e-mail: info@teletek-electronics.bg 18020247, Rev C, 04/ 2017...