Teletek electronics CA824 Installation Manual
Teletek electronics CA824 Installation Manual

Teletek electronics CA824 Installation Manual

Hide thumbs Also See for CA824:
Table of Contents

Advertisement

CA824

INSTALLATION MANUAL

3.3 version
WARNING
This manual contains information on limitations regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire manual should be carefully read.
September 2004

Advertisement

Table of Contents
loading

Summary of Contents for Teletek electronics CA824

  • Page 1: Installation Manual

    CA824 INSTALLATION MANUAL 3.3 version WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. September 2004...
  • Page 2: Table Of Contents

    Resources of PR864 Proxi Reader Module ..................23 Technical specifications of PR864 Proxi Reader module ..............23 SUPPLEMENT A - Menu structure chart for programming the CA824 alarm system ......24 ENGINEER PROGRAMMING MENU STRUCTURE CHART ............... 25 SUPPLEMENT B – Chart for user programmable menus ..............27...
  • Page 3: Introduction

    3. Avoid any connecting conductor loops in the box or their positioning above or below the printed-circuit board. 4. No additional relays should be placed in the CA824 Alarm system box, as switching these may cause electromagnetic interference. 4.1. Use only relays with good insulation between plugs and winding.
  • Page 4: Physical And Logical System Level

    PHYSICAL AND LOGICAL SYSTEM LEVEL Any security system established on CA824 principles should be regarded as a physical and logical entity. At its physical level it comprises of all modules, together with all their resources – inputs and outputs. Limitations at this level consist of the number of modules, which can be connected to the bus – no more than 15.
  • Page 5: Before Programming The Ca824 Alarm System

    Any arbitrary number of physical outputs can be connected to one PGM. These outputs can belong to different system devices. BEFORE PROGRAMMING THE CA824 ALARM SYSTEM Carefully read this manual to learn about system options and programming procedures. Any necessary changes to system configurations have to be set prior to programming, in order to com- ply with the specifications of your security system.
  • Page 6: Step-By-Step Programming Of System Parameters

    After Engineer programming mode is leaved all active zones and Tampers will affect in the system. Only one LCD keypad can be in Engineer programming at the same time. Engineer programming mode is allowed only when all areas in the system ar disarmed. CA824 Installation manual...
  • Page 7: Leaving Programming Mode

    NEW PnP HARDWARE IDENTIFICATION PROCEDURE Every module from the CA824 system set has a singular number, recorded during the production pro- cess. This number consists of two parts – batch number and device type, and is used to carry out the new hardware identification procedure or to load factory settings.
  • Page 8: Removing Modules From The System

    After this function is executed, communication with it the will be renewed. CA824 ALARM SYSTEM CHARACTERISTICS CA824 alarm system consists of CA824 control panel and up to 15 additional expander modules. Con- nection between modules is four wire common bus based on RS485.
  • Page 9: Ca824 Control Panel Box

    6 - TAMPER button for box self-protection Pull lid forward Lift lid up TAMPER button CA 864 control panel Undo screws Transmitter support strap Bottom Front lid Remove earthing cable Fig. 2 CA824 control panel box CA824 Installation manual...
  • Page 10 Use to fix main power supply cable Room for additional modules F - 0,63 A 12V / 7 Ah battery Mains transformer 50 / 60 Hz 15-25 V / 50VA Fig. 2a CA824 control panel plastic box CA824 Installation manual...
  • Page 11 (Wire EOL=OFF, DOUBLING=ON) Zone input Zone input 2,2K 2,2K TAMPER TAMPER With EOL, Open line and Short on line recognition (TAMPER) (Wire EOL=ON, DOUBLING=ON) Zone input 2,2K TAMPER TAMPER Fig. 3 Connecting sensors to CA824 system inputs CA824 Installation manual...
  • Page 12 ! When powering the system up after resetting factory configurations all system inputs are in OFF status - +12 V voltage! + PGM + PGM 1 kΩ Output x Output x Fig. 4. Connecting relay and light-emitting diode to CA824 output CA824 Installation manual...
  • Page 13: Ca824 Control Panel

    The scheme of the CA824 control panel is provided in Fig. 5. All CA824 system modules are connected via a quad system bus. The colours should correspond to the colours marked on the terminal of the modules (see Fig. 5).
  • Page 14: Ca824 Control Panel Resources

    OUT3 are programmable outputs. Output BELL has a power supply of up to 2 A to GND. The CA824 control panel has an integrated digital dialler for transmitting messages to the central moni- toring station via telephone line. The conductors from the telephone line socket are connected to termi- nals A and B.
  • Page 15: Technical Specification Of Ca824 Control Panel

    Technical specification of CA824 control panel Inputs - 8, can be expanded to 16 Outputs - 4 Quad system bus for connecting modules - Bus Connection Mains transformer - 15-25 V, 50 VA Battery charge - 13,8 V / 3 A...
  • Page 16: Lcd824 Keypad Module

    (sensors, light indicators, relays, etc.). This supply can be controlled by the processing block at the control panel and can be interrupted! LCD display Indicators Keys Protective lid Fig. 7. Front panel of CA824 LCD keypad CA824 Installation manual...
  • Page 17: Technical Specifications Of Lcd824 Keypad Module

    Consumption - nom 35 mA, max 60 mA Auxiliary devices power supply (+AUX and +PGM from control panel) - 13,8 V / 2 A Working temperature - (0°C) to (+50°C) LCD keypad dimensions - 115 x 135 x 25 mm CA824 Installation manual...
  • Page 18: Led816 Keypad Module

    The BLACK, GREEN, YELLOW and RED platforms are used to connect the module to the system bus. System / area status Zones 1 to 8 or first area zones Zones 9 to 16 or seccond area zones Protective lid Keys Fig. 10. LED816 keypad front panel CA824 Installation manual...
  • Page 19: Technical Specifications Of Led816 Keypad Module

    Consumption - nom 15 mA, max 60 mA Auxiliary devices power supply (+AUX and +PGM from control panel) - 13,8 V / 2 A Working temperature - (0°C) to (+50°C) LED kypad dimensions - 75 x 85 x 18 mm CA824 Installation manual...
  • Page 20: Mri4/8 Input (Zone) Expander Module

    Consumption - nom 15 mA, max 20 mA Auxiliary devices power supply (+AUX and +PGM from control panel) - 13,8 V / 2 A Working temperature - (0°C) to (+50°C) Inputs module dimensions - 92 x 43 mm CA824 Installation manual...
  • Page 21: Mro8 Output Expander Module Resources

    Consumption - nom 15 mA, max 100 mA Auxiliary devices power supply (+AUX and +PGM from control panel) - 13,8 V / 2 A Working temperature - (0°C) to (+50°C) PGM expander module dimensions - 92 x 43 mm CA824 Installation manual...
  • Page 22: Installation Box For Input And Output Expander Modules

    Fig. 15. The self-protection key is installed and configured by the producer. Technical specifications of the expander installation box Box dimensions - 128 x 103 x 54 mm CA824 Installation manual...
  • Page 23 The producer has provided additional positions for extra modules and devices for the plastic box (fig. 15a). Up to four expanders for inputs and/or outputs can be fitted together with control panel and accumulator, as it is shown on fig. 15a. CA824 Installation manual...
  • Page 24: Dio32 Module (Dynamic Indication)

    Two ….. type couplings have been placed on the board. These couplings are designed to connect the light-emitting diodes at the mnemo-panel. The Anode/Cathode correspondence has to be observed when connecting these light-emitting diodes – Fig. 16 – Anode row and Cathode row. !Connect light-emitting diodes only to the light-emitting diode indication outputs! CA824 Installation manual...
  • Page 25: Adjusting The Dio32 Module

    Auxiliary devices power supply (+AUX and +PGM from control panel) - 13,8 V / 2 A Working temperature - (0°C) to (+50°C) DIO module dimensions - 125 x 85 mm Support openings dimensions - 114 x 67 mm CA824 Installation manual...
  • Page 26: Pr864 Proxi Reader Module

    Number of outputs – one relay with normally open contact to plug the power supply to the electronic lock. Quad system bus for connecting to control panel - Bus Connection Consumption - max 170 mA Working temperature - (0°C) to (+50°C) CA824 Installation manual...
  • Page 27: Supplement A - Menu Structure Chart For Programming The Ca824 Alarm System

    SUPPLEMENT A - Menu structure chart for programming the CA824 alarm system The programming chart allows for quick scan of all program menus for the CA864 Alarm System con- figurations. There are two options for attaining to a specific programming menu.
  • Page 28: Engineer Programming Menu Structure Chart

    3)Attach to Area - Doubling 24h Burglary - Wire EOL Fire Panic Tamper Medical 24h Technical Keyswitch 4)Parameters - AutoZoneShutD. - Bypass enabled - Stay - Force - Double knock - Chime - Audible To Outputs Menu CA824 Installation manual...
  • Page 29 1)PC phone N: 2)Number Of rings 3)Panel ID number 4)PC ID number 5)Call Back 6)Answer machine 8)System edit 0)Device config 0)Inputs config Device 01 . . . 16 1)Add hardware 1)Outputs config 2)Assign trouble 3)Disable 4)Enable 9)Engineer out 5)Remove CA824 Installation manual...
  • Page 30: Supplement B - Chart For User Programmable Menus

    1) Back light 2) Entry Rights 2) Private Display 3) Remove Card 3) Edit Logo Memory (Log file) 0) All Areas 1) Select Area 01 Area name . . . TRBL (troubles) BPS (Bypass zone) 16 Area name CA824 Installation manual...
  • Page 31 The closest equivalent product, available at the time, shall replace the products manufacturer deems unrepairable. The current market price shall be charged for every replaced product. CA824 Installation manual...