Teletek electronics CA62 Installation And Programming Manual page 21

Alarm control panel
Table of Contents

Advertisement

ADDReSS 0011 - AUtHoRItY CoDe DURING AMBUSH (AMBUSH CoDe)
Ambush
Enabling/ Disabling the ambush code in the system. The parameter status can be changed with press-
Code
ing of random button of the keyboard.
No
Disabled ambush code.
Enabled ambush code. The code is made up by add-
ing 1 to a legal user code. There is no carrying over for
YeS
codes ending in the figure 9.
For example, the ambush code for 1234 is 1235, and
for 9999 it is 9990.
-
Default settings
NO
ADDReSS 0012 - eNABLeD KeYBoARD BLoCKING IN CASe oF ACCeSS CoDe eRRoR
Enabling/ Disabling blocking the keyboards buttons in case of wrong code entry. The parameter status
enable key-
pad block
can be changed with pressing of random button of the keyboard.
No
No keyboard blocking in case of wrong code entry.
The keyboard buttons will be blocked for 30 sec. if three
wrong codes are entered in sequence - for 30 seconds
YeS
the keyboard buttons are disabled, and a continuous
sound signal is heard.
-
Default settings
NO
ADDReSS 0013 - teCHNICAL tRoUBLe INDICAtIoN MASK
The mask for sound indication (two short beeps in every 20 seconds) from the keyboard in Technical
Trouble mode is assigned at this address.
The trouble indication mask is enabling with pressing a button with the respective number from 1 to
6 - see item 2.14.1 for the trouble indication in the system. Pressing the button with the same number
again will disable the trouble indication mask for the respective technical problem.
Only those LEDs whose numbers correspond to technical problems for which sound indications are
available will light up on the display at the end of the procedure. The set parameters are confirmed with
pressing the ENT button.
trouble
The procedure for enabling/ disabling the trouble mask indication are the same for all types and mod-
mask
els CA62 keyboards.
Example for disabling a trouble indication mask using LCD62 keyboard:
1. АС Loss
Loss of 220 V mains supply.
2. ВАТТ
Drop in battery charge, no battery or burnt out F1 battery fuse.
Low
3. Blown
Burnt out PGM fuse.
Fuse
4. No tel.
Loss of telephone line.
line
5. СОММ
Central station communication failure.
error
6. tAMPeR
Activated TAMPER within the system.
-
Default settings
AC Loss, ВАТТ Low, Blown Fuse, No Tel. Line, СОММ Error, TAMPER
Installation and Programming Manual - СА62 Alarm Control Panel
Indication
LeD
1 2 3 4 5 6
     
Indication
LeD
(1) (2) (3) (4) (5) (6)
     
Indication
LeD
1 2 3 4 5 6
     
Indication
LeD
(1) (2) (3) (4) (5) (6)
     
21
LCD
LCD
LCD
LCD

Advertisement

Table of Contents
loading

Table of Contents