Programming Of Proxi Readers - Teletek electronics CA62 Installation And Programming Manual

Alarm control panel
Table of Contents

Advertisement

The arming of the partition(s) is with specifying the arming mode type: Full, Stay or Instant.
Example:
With assigning this parameter, the system arming will be as follows:
6. Arm *
ARM or
Following
ARM or
ARM or
* NOTE: The Arm Following procedure is applied to user codes attached only to one of the Partitions.
Default settings - Arm Following
ADDReSSeS 7020 ... 7023 – KeYBoARD 2 PRoGRAMMING
The programming is the same as at ADDRESSES 7010 - 7013, as the programming is for Keyboard 2.
Default settings: Configuration - PARTITION А, Zone Enable; Left arrow - ARM Following; Right arrow - ARM
Following; ARM button - ARM Following
ADDReSSeS 7030 ... 7033 – KeYBoARD 3 PRoGRAMMING
The programming is the same as at ADDRESSES 7010 - 7013, as the programming is for Keyboard 3.
Default settings: Configuration - PARTITION А, Zone Enable; Left arrow - ARM Following; Right arrow - ARM
Following; ARM button - ARM Following
ADDReSSeS 7040 ... 7043 – KeYBoARD 4 PRoGRAMMING
The programming is the same as at ADDRESSES 7010 - 7013, as the programming is for Keyboard 4.
Default settings: Configuration - PARTITION А, Zone Enable; Left arrow - ARM Following; Right arrow - ARM
Following; ARM button - ARM Following

7.2 Programming of Proxi Readers

At ADDRESSES 71хх are programmed the parameters and the attributes for the connected to the system proximity
card readers. Up to 2 readers can be connected in the system.
ADDReSS 7100 - PRoXI ReADeR 1 SettINGS
At this address the parameters of Proxi Reader 1 are assigned.
Pressing them each time will alternatively change the status of the parameter - active / inactive.
Note: Every Proxi Reader can be attached to the both partitions in the system. In this case, if a proxi
card with user rights for the both partitions in the system is approached to the reader - the both parti-
tions will be armed or disarmed according their current status. If the one partition is armed and the
Proxi 1
other is disarmed, then approaching the same user card will disarm the armed partition. The next ap-
Settings
proaching of the user card will arm the both partitions again.
The Proxi Reader is attached to Partition А.
1. PARt A
Note: When the Proxi Reader is attached to Partition A only, then with approaching a user card with the
respective rights, if the Partition A is disarmed - it arms, if the Partition A is armed - it disarms.
The Proxi Reader is attached to Partition В.
2. PARt B
Note: When the Proxi Reader is attached to Partition B only, then with approaching a user card with
the respective rights, if the Partition A is disarmed - it arms, if the Partition B is armed - it disarms.
Default settings - PART A
ADDReSS 7110 - PRoXI ReADeR 2 SettINGS
The programming is the same as ADDRESS 7100, as the programming is for Proxi Reader 2.
Default settings: PART А
Installation and Programming Manual - СА62 Alarm Control Panel
+ 0 - Full Arming Mode
+ 1 - Stay Arming Mode
+ 2 - Instant Arming Mode
At the default settings the display will show:
LeD
     
LCD
(1) 2 3 4 5 6
49

Advertisement

Table of Contents
loading