ADDRESS 4016 - PROGRAMMING OF ATTRIBUTES FOR PARTITION А
The attributes of Partition A are programmed at this address. Every attribute is activated with pressing
of a digit button with a respective number (from 1 to 4). The chosen attribute is indicated with activated
Attributes
number of the pressed digit.
Partition А
Next pressing of the same button number will deactivate the attribute. At end of the procedure at the
keyboard display have to active only the numbers of the assigned attributes.
More than one attribute can be assigned at this address.
1. Squeak
The siren will activate singly for 1 second when arming the Partition A in the system.
ARM
2. Squeak
The siren will activate twice when disarming the Partition A in the system.
DISARM
3. Auto-Arm
Enabling the automatic arming of Partition A in the system for the
enbl
programmed ar ADDRESS 4014 Auto-ARM time.
Automatic arming the Partition A with specifying the arming mode:
4. Auto Arm
• Full
Full/Stay
• Stay (the User can stay at some rooms).
ADDRESS 4017 - NUMBER FOR COMMUNICATION WITH PARTITION А
Number for
A number for communication between Partition A and a central monitoring station is entered at this
communica-
address.
tion
4 digits have to be entered. The valid digits are from 0 to 9 and symbols from A to F.
Default settings - FFFF
ADDReSSeS 4020 ... 4024 - PRoGRAMMING oF tHe AttRIBUteS FoR PARtItIoN B
The programming is the same as for ADDRESS 4010 - 4014.
Default settings - Same as PARTITION A
ADDReSS 4025 - FIRe SIGNAL DURAtIoN FoR PARtItIoN B
The duration of the alarm signal for a FIRE event at Partition A is assigned at this address.
FIRe Signal
Programming this address affects the performance of the programmable SIREN output.
Duration
Every click of a digital button alternatively changes the type of duration of the sound signal. The display
Partition B
indication is shown in the tables.
Until a valid
There is a FIRE alarm signal until a valid system
user code is
user or master user code is introduced.
entered
Until the Bell
time at
The FIRE signal duration is set at address 4022
Address
BELL TIME.
4012 ends.
Default settings - Until a valid user code is entered
ADDReSSeS 4026 and 4027 - PRoGRAMMING oF tHe AttRIBUteS FoR PARtItIoN B
The programming is the same as for ADDRESS 4016 and 4017.
Default settings - Same as PARTITION A
Installation and Programming Manual - СА62 Alarm Control Panel
Auto-Arm
enbl
Disabled
Enabled
Attribute
Full
Stay
Indication
LeD
     
1 2 3 4 5 6
Indication
LeD
(1) (2) (3) (4) (5) (6)
     
41
Indication
LeD
LCD
3
(3)
Indication
LeD
LCD
4
(4)
LCD