SUPPLeMeNtS - СА62 Alarm Control Panel
Code
AR
AC Restore
AT
AC Loss
BA
Burglary alarm
BB
Burglary bypass
BH
Burglary Restore
BU
Burglary bypass Restore
CL
Quick arm
CL
Arming by user
CQ Remote arming
CS
Arming by keyswitch
FA
Fire alarm
FB
Fire bypass
FH
Fire Restore
FU
Fire bypass Restore
GA Gas detector
GH Low bottled gas level restore
GR Gas detector restore
GT
Low bottled gas level
HA
Ambush code
IA
Foil break
IR
Foil break restore
KA
High temperature
KR
High temperature restore
LB
Program mode entry
LX
Program mode exit
MA Medical alarm
MB Medical bypass
MH Medical Restore
MU Medical bypass Restore
NR GSM Link trouble restore
NT
GSM Link trouble
OP Disarm by user
OQ Remote disarm
OS Disarm by keyswitch
PA
Panic alarm
PB
Panic bypass
PH
Panic Restore
PU
Panic bypass Restore
RP
Periodic TEST report
RX
Manual TEST report
TA
Tamper alarm
TB
Tamper bypass
TH
Tamper Restore
TU
Tamper bypass Restore
UA
Opening of zone with attr. Write to log Activated zone with attribute "Write to log"
UH Closing of zone with attr. Write to log
WA Water leakage
WR Water leakage restore

Table of protocol SIA transmitted codes from CA62

Restore 220V power supply
No 220 V power supply
Alarm
Bypassing an Entry/Exit, Follow or Instant type zone
Restore alarm
Restore after Bypassing an Entry/Exit, Follow or Instant type zone
Quick arming (no code)
Arming by user
Remote ARMING
Arming from key-switch
Fire alarm
Bypassing a FIRE type zone
Restore after Fire alarm
Restore after bypassing a FIRE type zone
Activated gas detector in the premises
Restored low bottled gas level
Restored gas detector
Activated detector for low bottled gas level
Code introduced under ambush
Foil break
Restored foil break
High temperature in the premises
Restored normal temperature in the premises
Engineer programming mode entry
Engineer programming mode exit
Medical alarm
Bypassing a Medical type zone
Restore after Medical alarm
Restore after bypassing a Medical type zone
Restored GSM communication link
GSM communication link trouble
Disarming by user
Remote disarming
Disarming from key-switch
Panic alarm
Bypassing a Panic type zone
Bypassing a Panic type zone
Restore after bypassing a Panic type zone
Periodic TEST signal
Manual TEST signal
Tamper alarm
Bypassing a Tamper type zone
Restore after Tamper alarm
Restore after bypassing a Tamper type zone
Restored zone with attribute "Write to log"
Activated water leakage detector
Restored water leakage detector