6.1 General parameters

At ADDRESSES 60хх are programmed common parameters of the connected to the system communication devices.
Note: Delete the queue of events to be sent to Address 0023 by single pressing the 0 button before configuring com-
municator parameters of the digital communicator.
ADDReSS 6001 - NUMBeR oF CoMMUNICAtIoN AtteMPtS
Assign the number of attempts to connect to the central station for telephone monitoring and the
number of repetitions of voice messages at this address that the Control Panel will make in case of
unsuccessful communication or failure to acknowledge voice messages.
The value assigned at this address is the number of attempts to be made for each of the telephones
configured at addresses 6010 and 6020 - for the digital communicator, and at addresses 6031, 6032,
6033 and 6034 - for the voice dialer. (Example: if the assigned value is 4 and two telephone numbers,
the number of attempts which will be made are 8 - 4 for each telephone number). Any messages to the
central station will have priority. The attempts to connect to the central station will be terminated after
the assigned number is reached. Transmission of the occurred events begins via the voice dialer to
Number of
the telephones at addresses 6031 to 6034. The panel waits for 2 sec. after each "individual message"
communica-
in order to receive a message reception acknowledgement.
tion attempts
This is confirmed when the user presses key 9 on the telephone. The time needed to transmit one
group of voice messages, where no confirmation has been received, is up to 1 minute. The transmis-
sion to the other telephones begins after confirmation has been received from one single telephone.
After the assigned number of voice message transmissions is reached, the attempts to transmit voice
messages will be terminated. The attempts to transmit will be renewed to the central station first, when
the next transmission event occurs.
The values between 0 and 9 are permitted. The desired value is entered by single-pressing the key of
the respective figure. Where the value of 0 is entered, the panel will automatically implicate the value
of 4 for the central station and the value of 2 for the voice dialer.
Default settings - 0
ADDReSS 6002 - teSt MeSSAGe tRANSMIttING PeRIoD
Duration of transmission of test message in hours (HH) from 00 to 99 is entered.
The indication is hexadecimal.
test period
Two digits must be entered. When entering a period shorter than 10 hours the first digit must
be 0.
Default settings - 24 hours
ADDReSS 6003 - SettING teSt StARt tIMe FoR SeNDING MeSSAGe
At this address is set the first hour, at which the test message will start to be transmitted to central
monitoring station. Hours and minutes are entered (HH:MM), as the entered time is the time of start-
test start
ing the first test.
time
The next test time will start after the assigned at ADDRESS 6002 test period.
The indication is hexadecimal.
Default settings - 00:05 h.
ADDReSS 6010 - eNteRING teLePHoNe NUMBeR 1 FoR tHe CoMMUNICAtoR
A telephone number is assigned for communicating with central station - No. 1.
The indication is hexadecimal. The telephone number must not exceed 16 characters.
Some special functions can be entered by using the next button combinations:
1. Buttons ARM + 0 - Switches on "pulse dialer".
2. Buttons ARM + 1 - Switches on "tone dialer".
telephone
3. Buttons ARM + 2 - 2 seconds pause.
number 1
4. Buttons ARM + 3 - Switches on "Wait dial tone".
for the com-
5. Buttons ARM + 4 - "Blind dialing"; Switches off "Wait dial tone".
municator
6. Buttons ARM + 5 - Deletes the entered telephone number*.
Dialing has been assigned a default tone signal and "Wait dial tone" function is switched on.
The entered telephone number and the special functions can be saved with pressing the ENT button.
* Note: When there are no entered phone numbers at this address, use this key combination to disable
the option "listening to the telephone line".
Default settings - there are no configured numbers, tone dialer