Teletek electronics CA62 Installation And Programming Manual page 27

Alarm control panel
Table of Contents

Advertisement

All the ADDRESS for User code attributes from 2 to 20 are programmed in the same way as ADDRESS 1010:
- ADDReSS 1020 - USER CODE 2 ATTRIBUTES
- ADDReSS 1030 - USER CODE 3 ATTRIBUTES
...
- ADDReSS 1090 - USER CODE 9 ATTRIBUTES
- ADDReSS 1100 - USER CODE 10 ATTRIBUTES
...
- ADDReSS 1190 - USER CODE 19 ATTRIBUTES
- ADDReSS 1200 - USER CODE 20 ATTRIBUTES
At ADDRESSES for User code attributes from 2 to 20 no code combination has been introduced, and the default set-
tings for all of them are: DISARM, STAY ARM, BYPASS, PROGRAM, PART A.
ADDReSS 1210 - CHIeF MANAGeR CoDe AttRIBUteS
MANAGER CODE attributes are assigned at this address.
The manager code can have two attributes. Pressing a digital button with the respective number ac-
tivates the given attribute. The selected attribute is indicated with active number of the pressed digit.
Pressing the same digit again will inactivate the attribute
Only those numbers, which correspond to the assigned attributes, will remain active at the end of the
Chief
procedure. Pressing the ENTER button confirms the programmed attributes.
Manager
Partition А
5. PARt A
Authorizes the Manager code to operate with Partition A in the security area (bypass, arm, disarm,
etc).
Partition В
6. PARt B
Authorizes the Manager code to operate with Partition B in the security area (bypass, arm, disarm,
etc).
-
Default settings
PART A, PART B; Access code 0000
ADDReSS 1220 - MANAGeR 1 CoDe AttRIBUteS
MANAGER 1 CODE attributes are assigned at this address.
Manager 1
The programming is the same as for ADDRESS 1210.
No code combination is set.
ADDReSS 1230 - MANAGeR 2 CoDe AttRIBUteS
MANAGER 2 CODE attributes are assigned at this address.
Manager 2
The programming is the same as for ADDRESS 1210.
No code combination is set.
ADDReSS 1240 - MANAGeR 3 CoDe AttRIBUteS
MANAGER 3 CODE attributes are assigned at this address.
Manager 3
The programming is the same as for ADDRESS 1210.
No code combination is set.
Installation and Programming Manual - СА62 Alarm Control Panel
Indication at Default settings
LeD
     