Installation and Programming Manual - СА62 Alarm Control Panel
ADDReSS 1000 - DeFAULt CoNFIGURAtIoN SettING
Setting of
CA62 Alarm control panel supports 4 default parameter configurations.
default con-
Enter a number from 0 to 3 of a default configuration.
figuration
All the menus in this manual are described for the DEFAULT CONFIGURATION 0.
Default settings - 0
ADDReSS 1001 - PRoGRAMMING tHe CoDe DIGItS
The system allows using 4 and 6 digits codes.
Note: When switching from 4- to 6-digits code, the figures 00 will automatically be added at the
Number of
end. For example the 4-digits code 1234 will become 123400.
the code
IMPORTANT: When changing over from 6- to 4-digits code, only the first four figures in the
digits
4-digits code will remain valid. For example the 6-digits code 123456 will become 1234.
Due to risk of coincidence of codes, changing over from 6- to 4-digits code IS NOT RECOM-
MENDED!
The system Engineer, managers and users are using 4
4 digits
digit access codes.
The system Engineer, managers and users are using 6
6 digits
digit access codes.
-
Default settings
4 digits
ADDReSS 1010 - USeR CoDe 1 AttRIBUteS
USER CODE 1 attributes are assigned at this address.
The user code can have more than one attribute. Pressing a digital button with the respective number
activates the given attribute. The selected attribute is indicated with active number of the pressed digit.
Pressing the same digit again will inactivate the attribute
Only those numbers, which correspond to the assigned attributes, will remain active at the end of the
procedure. Pressing the ENTER button confirms the programmed attributes.
User Code 1
Disarming the system
1. DISARM
Authorizes this user code to Disarm the site.
Arming mode at which the user can stay in certain areas
2. StAY ARM
Authorizes this user code to arm those zones that have not been assigned a STAY attribute.
Zone Bypassing
3. BYPASS
Authorizes this user code to bypass zones in armed site.
Programming
4. PRoGRAM
Authorizes this user code to program system parameters.
Partition А
5. PARt A
Authorizes this user code to operate with Partition A in the security area (bypass, arm, disarm, etc).
Partition В
6. PARt B
Authorizes this user code to operate with Partition A in the security area (bypass, arm, disarm, etc).
-
Default settings
DISARM, STAY ARM, BYPASS, PROGRAM, PART А; No code*.
* Note: User codes in the system can be programmed only from the Manager Programming Menu.