  • Page 1: Installation Manual

    CA864 INSTALLATION MANUAL 3.4 version WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. August 2004...
  • Page 2: Table Of Contents

    Technical specifications of CA864 PC adapter module APC .............. 25 CA864 MEMOCARD module ......................25 SUPPLEMENT A - Menu structure chart for programming the CA864 alarm system ......26 SUPPLEMENT B – Chart for user programmable menus ..............30 CA864 Installation manual...
  • Page 3: Introduction

    3. Avoid any connecting conductor loops in the box or their positioning above or below the printed-circuit board. 4. No additional relays should be placed in the CA864 Alarm system box, as switching these may cause electromagnetic interference. 4.1. Use only relays with good insulation between plugs and winding.
  • Page 4: Installing Ca864 Alarm System Modules

    INSTALLING CA864 ALARM SYSTEM MODULES 1. First read this manual to find out about the features of the CA864 Alarm System modules and the installation procedures. 2. All necessary modules as well as the resources which are going to be used have to be defined before installation begins, in order to meet the specifications of your security system.
  • Page 5: Restoring Factory Settings

    “Single” (single access authorization) or “Always” (permanently authorized ac- cess). 6. Press 1 to allow engineer access to programming mode. 7. Press CLR until the TeleTek CA864 system message is displayed. 8. Enter Engineer Code. The default Engineer Code is “7777”. 9. You have now accessed programming mode.
  • Page 6: Leaving Programming Mode

    Procedure PnP for Identification of New Hardware Each module of the set of the CA864 system has a unique number recorded in the manufacturing process. It is with this number that the device will take part in the exchange on the bus. The number consists of the serial number of the device plus a two-digit code corresponding to the module type.
  • Page 7: Replacement Of A Defective Module

    Disable address, where x.x. is the shortcut address of the module. 2. If necessary, the module can be enabled again and integrated into the normal operation of the system with a command from the 8.0.x.x.4 Enable address, where x.x. is the shortcut address of the module. CA864 Installation manual...
  • Page 8 6 - TAMPER button for box self-protection Pull lid forward Lift lid up TAMPER button CA 864 control panel Undo screws 1 Transmitter support strap Bottom Front lid Remove earthing cable Fig. 2 CA864 control panel metal box CA864 Installation manual...
  • Page 9: Ca864 Control Panel Box

    Use to fix BUS CONNECTION main power supply cable Room for additional modules F - 0,63 A 12V / 7 Ah battery Mains transformer 50 / 60 Hz 15-25 V / 50VA Fig. 2a CA864 control panel plastic box CA864 Installation manual...
  • Page 10 (Wire EOL=OFF, DOUBLING=ON) Zone input Zone input 2,2K 2,2K TAMPER TAMPER With EOL, Open line and Short on line recognition (TAMPER) (Wire EOL=ON, DOUBLING=ON) Zone input 2,2K TAMPER TAMPER Fig. 3 Connecting sensors to CA864 system inputs CA864 Installation manual...
  • Page 11 ! When powering the system up after resetting factory configurations all system inputs are in OFF status - +12 V voltage! + PGM + PGM 1 kΩ Output x Output x Fig. 4. Connecting relay and light-emitting diode to CA864 output CA864 Installation manual...
  • Page 12: Ca864 Control Panel

    The scheme of the CA864 control panel is provided in Fig. 5. All CA864 system modules are connected via a quad system bus. The colours should correspond to the colours marked on the terminal of the modules (see Fig. 5).
  • Page 13: Ca864 Control Panel Resources

    Outputs OUT2, OUT3 and OUT4 are programmable outputs. Output OUT5 has a power supply of up to 2 A to GND. The CA864 control panel has an integrated digital dialler for transmitting messages to the central moni- toring station via telephone line. The conductors from the telephone line socket are connected to termi- nals A and B.
  • Page 14: Technical Specification Ofca864 Control Panel

    CA864 control panel fuses F BATT fuss – A 3A battery fuss. F AUX fuss – A 2A peripheral device power supply fuss. Output at + AUX. F PGM fuss – A 2A power supply fuse for PGMx and +PGM outputs.
  • Page 15: Lcd Keypad Module Resources

    (sensors, light indicators, relays, etc.). This supply can be controlled by the processing block at the control panel and can be interrupted! TeleTek LCD display Indicators Keys Protective lid Fig. 7. Front panel of CA864 LCD keypad CA864 Installation manual...
  • Page 16: Technical Specifications Of Ca864 Lcd Keypad Module

    YELLOW ZONE IN Fig. 9. CA864 LCD keypad motherboard Technical specifications of CA864 LCD keypad module Inputs - 1, can be expanded to 2 Outputs - 1 Quad system bus for connecting to control panel Consumption - nom 35 mA, max 60 mA Auxiliary devices power supply (+AUX and +PGM from control panel) - 13,8 V / 2 A Working temperature - (0°C) to (+50°C)
  • Page 17: Ca864 Led Keypad Module

    The BLACK, GREEN, YELLOW and RED platforms are used to connect the module to the system bus. System / area status Zones 1 to 8 or first area zones Zones 9 to 16 or seccond area zones Protective lid Keys Fig. 10. CA864 LED keypad front panel CA864 Installation manual...
  • Page 18: Technical Specifications Of Ca864 Led Keypad Module

    Support openings Fig. 11. CA864 LED keypad bottom TAMPER Fig. 12. CA864 LED keypad motherboard Technical specifications of CA864 LED keypad module Inputs - none Outputs - none Quad system bus for connecting to control panel Consumption - nom 15 mA, max 60 mA Auxiliary devices power supply (+AUX and +PGM from control panel) - 13,8 V / 2 A Working temperature - (0°C) to (+50°C)
  • Page 19: Technical Specifications Of Ca864 Input Expander Module Mri4/8

    TAMPER LOOP SERVICE LED Fig. 13 CA864 input expander MRI4/8 Technical specifications of CA864 input expander module MRI4/8 Inputs - 4, can be expanded to 8 Outputs - 2 Quad system bus for connecting to control panel – Bus Connection...
  • Page 20: Output Expander Module Mro8 Resources

    SERVICE LED TAMPER LOOP Fig. 14 PGM output expander MRO8 Technical specifications of CA864 output expander module MRO8 Inputs - none Outputs - 8 Quad system bus for connecting to control panel – Bus Connection...
  • Page 21: Technical Specifications Of The Expander Installation Box

    Fig. 15. The self-protection key is installed and configured by the producer. Technical specifications of the expander installation box Box dimensions - 128 x 103 x 54 mm CA864 Installation manual...
  • Page 22 The producer has provided additional positions for extra modules and devices for the plastic box (fig. 15a). Up to four expanders for inputs and/or outputs can be fitted together with control panel and accumulator, as it is shown on fig. 15a. CA864 Installation manual...
  • Page 23: Ca 864 Dio32 Module (Dynamic Indication)

    1 - 32 / 33 - 64 TEST Support openings Fig. 16 CA864 DIO dynamic indication module CA864 DIO32 module resources The DIO module has one programmable output marked PGM. This is a potential output. The program- mable PGM output has been duplicated by a “dry” contact relay. The relay contacts are labelled COM, NO and NC.
  • Page 24: Adjusting The Ca864 Dio32 Module

    !Mnemo-panel operation mode will automatically resume if the TEST button is not pressed within 30 seconds! Technical specifications of CA864 DIO32 module Inputs - none Outputs - 1 potential, duplicated with relay; sound indication option together with output status indication...
  • Page 25: Proxi Reader Module Ca864

    The plugs in the control panel +AUX and +PGM are used for any additional devices (relays, sound indicators, etc.). Technical specifications of Proxi Reader CA864 module Inputs - none Number of outputs – one relay with normally open contact to plug the power supply to the electronic lock.
  • Page 26: Ca864 Printer Module Apr

    Indication of the status of the printer and of the work mode control can be done through the engineer programming mode. The procedures for working the printer module are given in the CA864 Alarm System Programming Manual. Technical specifications of CA864 printer module APR Quad system bus for connecting to control panel –...
  • Page 27: Supplement A - Menu Structure Chart For Programming The Ca864 Alarm System

    SUPPLEMENT A - Menu structure chart for programming the CA864 alarm system The programming chart allows for a quick scan of all menus for configuration programming of the CA864 Alarm System. There are two ways to access a specific programming menu.
  • Page 28 0) Areas: 12345678 2) User Attributes 1) Areas 9-16 C.96 - Code Name 3) User Timeslot 4) User Proxi Card 0) Add Card 1) Code Length 1) Arm/D Rights 2) ChangeEng.Code 2) Entry Rights 3) Remove Card To Zones CA864 Installation manual...
  • Page 29 3) Bell Options 1) Area assign Device 01 . . 32 0) Assign to A 1-8 4) Bell Cut-off time 1) Assign to A 9-16 5) Assign Timeslot 6) Exit Time 7) Disarm Options To Dialer Menu CA864 Installation manual...
  • Page 30 8) System edit 0) Device config 0) Inputs config 01 device . . . 1) Outputs config 2) Assign Trouble 32 device 1) Add hardware 3) Disable 2) Info 4) Enable 5) Remove 6) Replace device 9) Engineer out CA864 Installation manual...
  • Page 31: Supplement B - Chart For User Programmable Menus

    1) Back light 2) Entry Rights 2) Private Display 3) Remove Card 3) Edit Logo Memory (Log file) 0) All Areas 1) Select Area 01 Area name . . . TRBL (troubles) BPS (Bypass zone) 16 Area name CA864 Installation manual...
  • Page 32 The closest equivalent product, available at the time, shall replace the products manufacturer deems unrepairable. The current market price shall be charged for every replaced product. CA864 Installation manual...