Follow zone
An alarm zone which is active only when the site is armed. The zone operates
instantaneously and activates the programmable ALARM and SIREN type
outputs, and the communicator.
2. Follow
Activating the zone during entry or exit time does not cause an alarm event.
When the system is disarmed, the activation of a zone is indicated by blink-
ing of the respective light-emitting diode for the zone (LED keyboards) or
enclosed in brackets zone number (LCD keyboards) for the time that the zone
remains open.
Follow zone
An alarm zone which is active only when the site is armed. The zone operates
instantaneously and activates the programmable ALARM and SIREN type
outputs, and the communicator.
3. Instant
Activating the zone during entry or exit time does not cause an alarm event.
When the system is disarmed, the activation of the zone is indicated with ac-
tive zone number for the time that the zone remains open.
An INSTANT type zone can be violated while Exit time is running if at AD-
DReSS 2001 the "Enabled Instant" parameter is enabled.
24-hour fire zone
Allows connecting 12 V fire detectors to the system.
4. Fire
These should avail of a normally closed relay output in inactive status.
Any activation of the zone will trigger off SIREN type outputs, the program-
mable FIRE type outputs and the station communicator.
24-hour panic type zone
Silent panic (2.Silent attribute is set on ADDRESS 2хх2, where хх is the
zone number) - only the programmable PANIC type outputs and the station
communicator can be activated. The respective LED (zone number at LCD
keyboard) blinks while the zone is active. There is no memory indication. After
a legal user code is entered, the MEMORY LED and the activated zone LED
(zone number at LCD keyboard) both light up continuously.
5. Panic
Sound panic - the SIREN output, the programmable PANIC type outputs
and the station communicator are activated. The sirens are instantaneously
activated irrespective of the programmed time delay. Activating the zone will
cause the MEMORY LED and the activated zone LED (zone number at LCD
keyboard) to light up continuously.
The indication of the memory can be deleted by entering a legal user code, a
manager code or during the next arming.
24-hour tamper type zone
Activating this zone type triggers off the SIREN output, the programmable
TAMPER type outputs and the station communicator. Any activation of the
zone would trigger off a sound signal from the keyboard buzzer when the
6. tamper
system is disarmed and the TAMPER siren output has been programmed as
SILENT at ADDReSS 0017.
The indication of the memory can be deleted by entering a legal user code or
manager code or during the next arming.
24-hour medical type zone
Assigning this zone type will set the programmable MEDICAL type outputs
active and will start the communicator. The activated zone LED (zone number
7. Medical
at LCD keyboard) will light up irrespective of the system status. The indication
of the memory can be deleted by entering a legal user code, manager code
or during the next arming.
Key-Switch, 24-hour burglary type zone.
When this zone type is assigned, the respective panel input is used to trans-
mit the arming and disarming signal with the help of a keyswitch.
The installer has to set the type of the zone activation:
8. Key-
• With an impulse (PULSE attribute is set at ADDRESS 2013);
Switch
• Reaction of open or in normal operation mode zone (LATCH attribute is set
at ADDRESS 2013).
Arming is only possible in Full Arm mode. Arming will be anticipated only when
the system is ready - all zones are inactive.
Installation and Programming Manual - СА62 Alarm Control Panel
ADDReSS 2010 description continues on page 30
29
Indication
LeD
     
LCD
1 2 3 4 (5) 6
Indication
LeD
     
LCD
1 2 3 4 (5) (6)
Indication
LeD
     
LCD
1 2 3 (4) 5 6
Indication
LeD
     
LCD
1 2 3 (4) 5 (6)
Indication
LeD
     
LCD
1 2 3 (4) (5) 6
Indication
LeD
     
LCD
1 2 3 (4) (5) (6)
Indication
LeD
     
LCD
1 2 (3) 4 5 6