Installation and Programming Manual - СА62 Alarm Control Panel
24-hour auxiliary type zone
When this zone type is assigned, respectively a number of AUX attribute
9. Auxiliary
should be programmed at ADDReSS 2xx4, where xx is the number of the
zone.
-
Default settings
0. Unused
ADDReSS 2011 - ZoNe 1 AttRIBUteS 1
Parameters "ATTRIBUTES 1" for ZONE 1 are programmed at this address.
More than one attribute can be assigned for the zone. Pressing a digital button with the respective
number will activate a given attribute. Every activated attribute number is indicated as a lighting on
LED or enclosed in brackets number. Pressing the same digital button again will deactivate the at-
tribute. At the end of this procedure, the LEDs or zone numbers, which correspond to the assigned
Zone 1
attributes only, will remain activated.
Attributes 1
the parameters "AttRIBUteS 1" are as follows:
1. Auto
Authorization for automatic Bypassing the zone after reaching the number of
Bypass
activations per armed mode as set in ADDReSS 2000.
Authorization to Bypass a zone. Assigning this attribute to the respective zone
2. Bypass
will authorize bypass of the zone on behalf of the system user or manager.
The zone is not going to be armed in the STAY mode. Assigning this attribute
3. Stay
to the respective zone will authorize the respective Stay mode zone arming.
If when arming the system the zone is open (activated), then the respective
Partition will be armed, and the respective zone will be armed after it is re-
4. Force
stored.
(There is a special indication for the LCD keyboards when this attribute is set
- when ARMING the system the middle window of the castle is blinking.)
DOUBLE KNOCK type zone. Assigning this attribute to the respective zone
authorizes Double Knock mode performance in the zone.
A 3-minute time interval starts when a detector in the zone is activated for the
5. Double
first time in armed mode. An alarm event is registered if a second detector
activation is recorded within this interval in the same or another zone.
An alarm event will also be registered if no zone is restored within 15 seconds
of the first activation of the zone sensor.
When armed the zone will perform as Entry/Exit type.
The system will be armed:
6. e/e Final
А) When the exit time is over;
B) immediacy after closing the entry-exit zone.
-
Default settings
AutoBypass, Bypass attributes
Indication at Default settings
LeD
(1) (2) 3 4 5 6
     
     
1 2 (3) 4 5 (6)
LCD
Attention:
This attribute is not
valid for zone types:
Fire, Panic, Medical
and Key-Switch.
Attention:
This attribute is valid
for all zone types, ex-
cept for Key-Switch.
Attention:
This attribute is not
valid for zone types:
Fire, Panic, Tamper,
Medical, Key-Switch
and Auxiliary.
Attention:
This attribute is not
valid for zone types:
Entry/Exit, Follow
and Key-Switch.
Attention:
This attribute is not
valid for zone types:
Fire, Panic, Medical
and Auxiliary.
Attention:
This attribute is valid
for zone type Entry/
Exit only.
Indication
LeD
LCD