ADDReSS 3010 - PGM1 AttRIBUteS 1 PRoGRAMMING
The events "ATTRIBUTES 1", which activate the programmable output PGM 1, are programmed at
this address.
An arbitrary combination of events, which activate the programmable output, is allowed. The output is
activated upon the occurrence of any of the programmed events and is restored when all programmed
PGM 1
events are discarded.
Attributes 1
Press a digital button, which corresponds, to a given attribute (alarm event). The attribute is selected
when the light-emitting diode on the display (LED keyboards) or an enclosed in brackets number (LCD
keyboards) with the respective number is activated. Next pressing of the same digit button will deac-
tivate the attribute.
It is activated when Entry\Exit, Follow and Instant type zones are violated while the system is in armed
mode and activating Fire, Panic, Tamper, Medical and AUX type zones irrespective of the system arm-
ing status.
1. ALARM
• With set attribute Pulse the output is restored after a valid user code is entered, restoring of the
activated zone or following an interval of 1 min.
• With set attribute Latch the output is restored after a valid user code with disarming rights is entered
or after confirmation for stopping the alarm if the system is disarmed.
It is activated when the PANIC type zone is triggered or when PANIC is triggered from the keyboard.
• With set attribute Pulse the output is restored after a valid user code is entered or following an
interval of 1 min.
2. PANIC
• With set attribute Latch the output is restored after a valid user code with disarming rights is entered
or after confirmation for stopping the alarm if the system is disarmed.
It is activated when TAMPER is triggered off in any zone or periphery device, irrespective of the arm
3. tAMPeR
mode. It is restored after activation is discarded and does not depend on the Pulse / Latch attribute.
It is activated when a FIRE type zone is triggered.
• With set attribute Pulse the output is restored after a valid user code is entered or following an
4. FIRe
interval of 1 min.
• With set attribute Latch the output is restored after a valid user code with disarming rights is entered
or after confirmation for stopping the alarm if the system is disarmed.
5. FIRe
It is activated for 4 sec. after a valid code is entered.
ReSet
It is activated by a command to arm the whole system (partition A and partition B). Output is restored
6. oN / oFF
after disarming of any of the partitions (A or B) and does not depend on the Pulse / Latch attribute.
-
Default settings
ALARM
ADDReSS 3011 - PGM1 AttRIBUteS 2 PRoGRAMMING
The events "ATTRIBUTES 2", which activate the programmable output PGM 1, are programmed at
this address.
An arbitrary combination of events, which activate the programmable output, is allowed. The output is
activated upon the occurrence of any of the programmed events and is restored when all programmed
PGM 1
events are discarded.
Attributes 2
Press a digital button, which corresponds, to a given attribute (alarm event). The attribute is selected
when the light-emitting diode on the display (LED keyboards) or an enclosed in brackets number (LCD
keyboards) with the respective number is activated. Next pressing of the same digit button will deac-
tivate the attribute.
It is activated when a MEDICAL type zone is triggered.
• With set attribute Pulse the output is restored after all MEDICAL type zones are restored.
1. MeDICAL
• With set attribute Latch the output is restored after all MEDICAL type zones are restored, after a
valid user code with disarming rights is entered or after confirmation for stopping the alarm if the sys-
tem is disarmed.
It is activated right after a zone has been designated to be bypassed or when the zone has been as-
2. PS /
signed a Stay ARM and Instant ARM type arming. Output is restored after de-bypassing of all zones
BYPASS
or after disarming.
Installation and Programming Manual - СА62 Alarm Control Panel

3. PGM AND SIReN oUtPUtS PRoGRAMMING

ADDReSS 3011 description continues on page 36