04.
AC LoSS
The output is activated in case of trouble in the main power supply of the control panel (control panel
Control
PCB).
Panel
MainBoard
The output is activated in case of activating of a ZONE with assigned Auxiliary type and AC LOSS at-
05.
tribute - for controlling of devices working together with the control panel, for example additional power
AC LoSS
supply devices. When the ZONE is activated the control panel will send a message for trouble.
From Zone
The output will be restored when the power supply of the zone is restored.
The output is activated in case of an alarm signal:
• FIRE in the system (for LED62)
06.
• MEDICAL Alarm (for LED62)
KeYPAD
• PANIC (for all types of keyboards)
ALARM
• in case of entering 3 wrong codes in sequence and blocking the keypad buttons (when a keyboard
blocking is enabled on address 0012)
• TAMPER from a keyboard
The output is activated in case of sending of FIRE signal - the FIRE button of LED62 (
07.
pressed and held on for 3 seconds.
KeYPAD FIRe
ALARM
Note: This parameter can be programmed only for LED62 keyboard!
08.
The output is activated in case of sending of PANIC alarm signal - the buttons CLR+ENT are pressed
KeYPAD
and held on for 3 seconds.
PANIC
Note: For LED62 keyboard this parameter can be programmed for the PANIC button -
ALARM
The output is activated in case of sending of "AMBUSH CODE".
The AMBUSH CODE is a personal code. The User can use the AMBUSH CODE if he is forced to dis-
arm the system. When an AMBUSH CODE is entered the system will be disarmed and a TROUBLE
09.
signal will be send to a central monitoring station.
AMBUS
The AMBUSH CODE for every user code is generated with adding 1 to the last digit. If the last digit of
CoDe
the code is 9 it is replaced with 0.
Example: Personal User Code: 4615 → Ambush Code: 4616
The output is activated in case of sending of CHIME signal from a zone with assigned CHIME attribute.
The output is restored automatically after 2-3 seconds and does not depend on the programming of
the Pulse / Latch parameter.
10. CHIMe
Note: The output depends on the programmed PARTITION attachment - for the zone and the PGM
output MUST be attached to one and the same PARTITION.
11.
The output is activated in case of sending of alarm signal from zones with assigned AUXILIARY at-
AUXILIARY
tribute and is restored when all AUXILIARY type zones are deactivated.
ALARM
12.
The output is activated in case of sending of alarm signal from AUXILIARY type zones with assigned
BAtteRY
BATT LOW attribute.
tRoUBLe
13.
Wireless
The output is activated in case of sending an alarm signal for wireless transmitter loss from AUXILIARY
transmitter
type zone with "GSM Link Trouble" assigned attribute.
Supervision
Loss
14.
Wireless
The output is activated in case of wireless transmitter low battery charge or battery loss from AUXIL-
transmitter
IARY type zone with "Battery Low" assigned attribute.
Battery Low
The output is activated in case of assigned "Auto-Arm" (Automatic arming of the system) attribute for
15.
PARTITION А (ADDRESS 4016), PARTITION В (ADDRESS 4026) or for both partitions. The output is
AUto-ARM
restored with disarming of the system and does not depend on Pulse/Latch programming.
Installation and Programming Manual - СА62 Alarm Control Panel
Personal User Code: 4619 → Ambush Code: 4610
ADDReSS 3013 description continues on page 38