The digital communicator has engaged the telephone line here. The voltage measured at terminals A
and B should read between 7.5 V DC and 10.5 V DC. At the same time the built-in Dial Tone Detector
2: Dial tone
is also activated - a detector for the DIAL signal.
Every time when the communicator identifies a dial tone signal, a beep sound from the keyboard will
be heard.
3: Low freq.
The digital communicator attributes low frequency to the telephone line.
4: High freq. The digital communicator attributes high frequency to the telephone line.
5: DtMF
The digital communicator attributes a DTMF signal.
ADDReSS 0030 - SettING tHe BUILt-IN CLoCK
The hours and minutes are set (HH:MM).
At LED keyboards the indication is hexadecimal and the digits are displayed one by one. To view the
Setting the
clock, the digits can be browsed with the help of the arrows.
clock
At LCD keyboards you can enter the hour and minutes directly from the keypad buttons, while the
position of the entered digit blinks.
Default settings - 00:00 h
ADDReSS 0031 - SettING tHe DAte
The date and month are set (DD.MM).
At LED keyboards the indication is hexadecimal and the digits are displayed one by one. To view the
Setting the
date, the digits can be browsed with the help of the arrows.
date
At LCD keyboards you can enter the date and month directly from the keypad buttons, while the posi-
tion of the entered digit blinks.
Default settings - 01:01
ADDReSS 0040 - CHIMe eNABLe/DISABLe
At this address the engineer can enable or disable the sound signalization (Chime) for opening of
Chime en-
an entry-exit type zone. The parameter status can be changed with pressing of random button of the
able/Disable
keyboard.
YeS
The Chime is Enabled.
No
The Chime is Disabled
Default settings - NO
ADDReSS 0099 - SoFtWARe ReVISIoN ReVIeW
The Engineer can review the number of current software revision of the CA62 control panel at this
address. The indication is hexadecimal. The software revision is displayed as 4-digit number. The
Software
numbers are displayed one by one as the engineer uses the arrow buttons to see them all. The format
revision
of the software revision is [XX.XX].
For example: reading [04.30] means software revision 4.3.