Sysreset; Ttl/Ecl Trigger Access Commands - Racal Instruments 1260-00C User Manual

Slot 0 / resource manager
Table of Contents

Advertisement

A24?

SYSRESET

TTL/ECL Trigger
Access
Commands
Local Command Set 4-46
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
A24
#h504305, #hA502
Purpose:
Read a word value from VXI A24 address space.
Query
Syntax:
A24?
<A24 address>
Response:
Program response:
<word value><CRLF>
Console response:
Value <hex word value> (<word value>)
read from A24 address <A42 hex address
(<A24 address>)<CRLF>
where <word value> is in decimal integer format,
<hex word value> is in C language
hexadecimal format, <A24 hex address> is in C
language hexadecimal format, and <A24
address> is in decimal integer format.
Example:
Read the word at A24 address 205634h.
A24?
#h205634
Purpose:
Remotely reset system.
Command
Syntax:
SYSRESET
Action: Asserts the VXI backplane signal SYSRESET*.
The TTL/ECL Trigger Access commands are described on the
following pages.
AckTrig
DisTrigSense
EnaTrigSense
GetTrigHndlr