Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Racal Instruments Manuals
Controller
1260-00C
User manual
Setting The Shared Memory Size; Table 3-3, 1260-00C Cpu Local And A24 Memory Ranges; Table 3-4, Shared Memory Switch Settings - Racal Instruments 1260-00C User Manual
Slot 0 / resource manager
Hide thumbs
Racal Instruments
1260-00C
User Manual
1
2
3
4
5
Table Of Contents
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
page
of
160
Go
/
160
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
1260-00C User Manual
Table 3-3. 1260-00C CPU Local and A24 Memory Ranges
Installed
Memory Size
512 kilobytes
1 Megabyte
2 Megabytes
4 Megabytes
Setting The Shared
Memory Size
Configured
Memory
Size
512 kilobytes
512 kilobytes
1 Megabyte
1 Megabyte
2 Megabytes
2 Megabytes
4 Megabytes
4 Megabytes
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Installed Memory
Local Address Range
Start
End
000000h
07FFFFh
000000h
0FFFFFh
000000h
1FFFFFh
000000h
3FFFFFh
To set the amount of installed memory shared with the VXIbus,
change the settings of switches S1 and S2. Table 3-4 gives the
S1 and S2 switch settings for sharing various portions of RAM with
the VXIbus for each possible installed memory configuration.
Table 3-4. Shared Memory Switch Settings
Amount of Installed Memory Shared With VXIbus
S1 ON
S1 OFF
S2 ON
S2 ON
256 kilobytes
512 kilobytes
1 Megabyte
2 Megabytes
The RAM shared with the VXIbus will be the upper portion
of the installed memory.
The 1260-00C Offset Register holds the shared memory VXI A24
base address, as described in the VXIbus specification. The RM
automatically configures the Offset Register at start-up.
Accessible VXI A24
Address Range
Start
080000h
E7FFFFh
100000h
E7FFFFh
200000h
E7FFFFh
400000h
E7FFFFh
S1 ON
S1 OFF
S2 OFF
S2 OFF
128 kilobytes
256 kilobytes
512 kilobytes
1 Megabyte
NOTE
Operation 3-5
End
None
None
None
None
Table of
Contents
Previous
Page
Next
Page
1
...
27
28
29
30
31
32
33
34
Advertisement
Table of Contents
Related Manuals for Racal Instruments 1260-00C
Controller Racal Instruments 1250 Series Manual
Universal switch controller (284 pages)
Related Products for Racal Instruments 1260-00C
Racal Instruments 1250 Series
Racal Instruments 1250-62
Racal Instruments 1250-63
Racal Instruments 1260-01T
Racal Instruments 1260-01
Racal Instruments 1260-01S
Racal Instruments 1260-30 Series
Racal 1260-30D
Racal Instruments 1260-14C
Racal Instruments 1260-37
Racal Instruments 1260-13
Racal Instruments 1260-36
Racal Instruments 1260-18
Racal Instruments 1260-64M
Racal Instruments 1260-172
Racal Instruments MULTIPLEXER PLUG-IN 1260-134
This manual is also suitable for:
1260-00b
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL