Dynamic Configuration Commands And Queries; Dcbnosend; Dcgrantdev - Racal Instruments 1260-00C User Manual

Slot 0 / resource manager
Table of Contents

Advertisement

Dynamic
Configuration
Commands and
Queries

DCBNOSend

DCGrantDev

Local Command Set 4-20
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Example:
Get self-test status for device at Logical Address
48.
StatusState? 48
The dynamic configuration (DC) commands and queries are
described in the following paragraphs.
DCBNOSend
DCGrantDev
DCSystem?
The DC commands are used to configure the VXI system when all
of these conditions are present:
The 1260-00C is the RM.
At least one DC device is present in the system.
The non-volatile configuration setup specifies not to send
Begin Normal Operation (user-specified hierarchy).
The system is still in the start-up Configure substate
(DCBNOSend has not been sent).
The DCSystem? query response indicates whether the system
contains a DC device. If the system is found to be a DC system,
the DCGrantDev command is used to configure the
Commander/Servant hierarchy. The DCBNOSend command is
used to end the DC phase and to cause the system to enter
normal operation.
Purpose:
Cause a DC system to exit the Configure substate
and enter the Normal Operation substate.
Command
Syntax:
DCBNOSend
Action:
Send the Begin Normal Operation command to all
top-level Commanders.
Purpose:
Grant a device to a Message-Based Commander in
1260-00C User Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

1260-00b