The standard view 1 (home screen) shows the operating states of the Sunny Island:
1
2
3
4
1
Row:
Uhrzeit in [hh:mm:ss]
2
Row:
grid or generator power in kW ("TotExtPwrAt")
ggf. Pfeil in Energieflussrichtung (z. B. Š = Einspeiseleistung PV-Generator)
Load power in kW ("TotExtPwrAt" + "TotInvPwrAt")
3
Row:
Symbols for grid / generator
Loads
Generator relay or load shedding relay: On = -
ggf. Pfeil in Energieflussrichtung (z. B. ‡)
4
Row:
state of charge of battery (SOC)
Symbol for battery
Pfeil in Energieflussrichtung ( ‰ = Entladen, Š = Laden)
Inverter power in kW ("TotInvPwrAt")
-
-
92
SI2012_2224-TEN082311
positive value: the battery is discharging/the Sunny Island is feeding the
loads
negative value: the battery is charging