SMA Sunny Island 2012 Technical Description page 103

Stand-alone grid inverter
Table of Contents

Advertisement

SMA Solar Technology AG
he password is dependent on the operating hours counter. In the installer level there are extended
T
access privileges to all necessary parameters.
Password = Sum of the digits of the number of operating hours.
Proceed as follows to enter the installer password:
The display shows the standard view 1.
1.
Select the "200# Settings" menu.
2.
Depress the knob.
3.
Select the "260# Set Password" menu.
4.
Depress the knob.
The following message appears:
Two place holders (** ) for the password
(PW)
Level [0] = user level
Operating hours (OnTmh)
Sum of all hours in operation
Units
5.
Calculating the password
Add up all the digits of the number of
operating hours. In this case:
1 +2 + 3 + 4 + 5 + 6 = 21
6.
Press the pushbutton. The place holders
blink.
7.
Enter the password (here: "21").
Turn the pushbutton to the right or left. The
value increases or decreases accordingly.
Technical Description
Operating the Sunny Island
100# Meters
200# Settings
300# Diagnosis
400# Failure/Event
230# Set External
240# Set Relay
250# Set System
260# Set Password
PW:**
Level[0]
OnTmh
123456
PW:21
Level[0]
OnTmh
123456
SI2012_2224-TEN082311
[h]
[h]
103