SMA Solar Technology AG
Cable conduits in the enclosure.
All cables are fed through the feed-troughs on the bottom side of the device (see following figure)
and connected to the appropriate connection terminals on the Sunny Island.
DC cable insertion
point
Cable screw joint with metric thread
Use the metric-thread cable screw connections provided to fasten the AC cables inside the Sunny
Island housing in a manner conforming to the appropriate norms. The metric-thread cable screw
connections guarantee a dust-free and waterproof installation of the cables in the housing and also
provide strain relief for the cable connection.
Close all unused openings in the housing using the appropriate dummy plugs.
Cable conduit gasket
NOTICE!
Damage to device can be caused by penetrating moisture
Install screw joints and cable conduit gaskets properly.
Seal unused conduits.
Properly installed screw joints and cable conduit gaskets guarantee to provide protection rating
IP54.
Technical Description
Cable conduit gasket
The cable conduit gasket allows simple connection of the
pre-assembled communication and control cables (with
RJ45 plugs).
Sunny Island Electrical Connection
Cable screw joint with
metric thread
SI2012_2224-TEN082311
41