Sign In
Upload
Manuals
Brands
SMA Manuals
Inverter
Sunny Central 500CP-JP
SMA Sunny Central 500CP-JP Manuals
Manuals and User Guides for SMA Sunny Central 500CP-JP. We have
4
SMA Sunny Central 500CP-JP manuals available for free PDF download: User Manual, Installation Manual, Maintenance Manual
SMA Sunny Central 500CP-JP User Manual (108 pages)
Brand:
SMA
| Category:
Inverter
| Size: 2 MB
Table of Contents
Table of Contents
3
Information on this Document
7
Safety
9
Intended Use
9
Safety Precautions
10
Skills of Qualified Persons
12
Personal Protective Equipment
13
Product Description
14
PV System Overview
14
Sunny Central
14
Design of the Sunny Central
14
Type Label
15
Operating Modes
16
Touch Display
18
Key Switch
18
Sunny Central Communication Controller
19
Sunny Central String-Monitor Controller
20
Remote Shutdown
20
External Fast Stop
21
Ground-Fault Monitoring and Insulation Monitoring
21
Mode of Operation
21
Ground-Fault Monitoring in Grounded PV Arrays
22
Ground Fault Detection and Interruption (GFDI)
22
Remote GFDI
23
Soft Grounding
24
Insulation Monitoring
25
Insulation Monitoring Device
25
Combined Insulation and Ground-Fault Monitoring
26
GFDI and Insulation Monitoring Device
26
Remote GFDI and Insulation Monitoring Device
26
Remote Soft Grounding and Insulation Monitoring Device
27
Grid Management Services
28
Requirements
28
Active Power Limitation
28
Reactive Power Setpoint
29
Behavior in the Absence of Active and Reactive Power Setpoints
29
Full and Limited Dynamic Grid Support (FRT)
29
Decoupling Protection Ramp
30
Grid Management Shutdown
30
Q at Night
31
Islanding Detection
32
Active Islanding Detection
32
Passive Islanding Detection
32
Schematic Diagram
32
Touch Display
33
Touch Display Layout
33
Explanation of Symbols
33
Status Info Line
33
Information Area
34
Navigation Line
36
Selecting the Language
36
Changing the Date, Time and Time Zone
37
Selecting the Display Format
37
Setting the Brightness
37
Entering the Installer Password
37
Network Settings
38
Communication with the Inverter
40
Displaying Instantaneous Values
40
Changing Parameters
40
Setting the String-Current Monitoring on the Sunny Central String-Monitor Controller
40
Optional Settings of the Sunny Central String-Monitor Controller
42
Changing the Communication Period
42
Changing the Monitoring Period
42
Assigning PV Strings to Different Measuring Channels
43
Assigning PV Strings to Different Groups
43
Setting the Tripping Time
43
Setting the Tolerance
44
Configuring the Remote Shutdown
44
Deactivating the "Fully Hermetic" Transformer Protection
44
Grid Monitoring
45
How Grid Monitoring Works
45
Setting Line Voltage Monitoring
45
Setting Power Frequency Monitoring
47
Grid Connection after Elimination of Error
47
Setting the Active Power Ramp-Up
47
Setting the Medium Voltage
48
Activating the Manual Resume Mode
48
Power Control
49
Active Power Limitation
49
Frequency-Dependent Active Power Limitation
49
Principle of Frequency-Dependent Active Power Limitation
49
Setting the Mode of Frequency-Dependent Active Power Limitation and Associated Parameters
50
Frequency-Independent Active Power Limitation
50
Selecting the Mode with the Parameter P-Wmod
50
No Active Power Limitation: off Mode
51
Active Power Limitation with Setpoint Command Via Modbus Protocol: Wctlcom Mode
51
Active Power Limitation with Absolute Value: Wcnst Mode
51
Active Power Limitation as a Percentage of Nominal Power: Varcnstnom Mode
51
Active Power Limitation Via Standard Signal: Wcnstnomanin Mode
52
Displaying the Status of Active Power Limitation
52
Displaying Error Messages and Warnings for Active Power Limitation
52
Reactive Power Control
53
Mode of Reactive Power Control
53
Selecting the Mode with the Parameter Q-Varmod
53
No Reactive Power Control: off Mode
54
Reactive Power Control with Setpoint Command Via Modbus Protocol: Varctlcom Mode
55
Reactive Power Control with Setpoint Command Via Modbus Protocol: Pfctlcom Mode
55
Reactive Power Control with Absolute Value: Varcnst Mode
55
Reactive Power Control as a Percentage of the Nominal Power: Varcnstnom Mode
55
Reactive Power Setpoint Via Standard Signal: Varcnstnomanin Mode
55
Reactive Power Setpoint Via Displacement Power Factor Cos Φ: Pfcnst Mode
56
Displacement Power Factor Cos Φ Via Standard Signal: Pfcnstanin Mode
56
Displacement Power Factor Cos Φ as a Function of Feed-In Power: Pfctlw Mode
57
Reactive Power as a Function of Line Voltage: Varctlvol Mode
58
Measures for Voltage Support through Parameterization of Reactive Power/Voltage Characteristic Curve: Varctlvolhystdb Mode
59
Measures for Voltage Support through Parameterization of Reactive Power/Voltage Characteristic Curve: Varctlvolhystdba Mode
62
Displaying Error Messages and Warnings for the Reactive Power Setpoint
63
Q at Night
63
Selecting Parameter Qodq-Varmod
63
No Q at Night: off Mode
65
Q at Night with Setpoint Command Via Modbus Protocol: Varctlcom Mode
65
Q at Night with Absolute Value: Varcnst Mode
65
Q at Night as a Percentage of the Nominal Power: Varcnstnom Mode
65
Q at Night Via Standard Signal: Varcnstnomanin Mode
65
Q at Night as a Function of Line Voltage: Varctlvol Mode
67
Measures for Voltage Support through Parameterization of Reactive Power/Voltage Characteristic Curve
68
Varctlvolhystdb Mode
68
Measures for Voltage Support through Parameterization of Reactive Power/Voltage Characteristic Curve
71
Varctlvolhystdba Mode
71
Setting the Insulation Monitoring of the PV System
72
Setting the PV System to Insulation Monitoring with GFDI and an Insulation Monitoring Device
72
Safety During Insulation Monitoring of the PV System with GFDI and an Insulation Monitoring Device
72
Switching to Insulated Operation
72
Switching to Grounded Operation
73
Setting the PV System to Insulation Monitoring with Remote GFDI and an Insulation Monitoring Device
73
Information on Insulation Monitoring of the PV System with Remote GFDI and an Insulation Monitoring Device
73
Switching to Insulated Operation
73
Setting the PV System to Insulation Monitoring with Remote Soft Grounding and an Insulation
74
Monitoring Device
74
Information on Insulating PV Modules with Remote Soft Grounding and an Insulation Monitoring Device
74
Switching to Insulated Operation
74
Switching to Grounded Operation
74
Troubleshooting
75
Safety During Troubleshooting
75
Reading off Disturbance Messages
75
Reading off Disturbance Messages Via Touch Display
75
Reading off Disturbance Messages Via User Interface
75
Acknowledging Disturbance Messages
75
Acknowledging Disturbance Messages Via the Key Switch
75
Acknowledging Error Messages Via the User Interface
76
Error Messages
76
Behavior of Sunny Central Inverters under Fault Conditions
76
Explanation of the Error Tables
77
Error Numbers 01Xx to 13Xx - Disturbance on the Utility Grid
78
Error Number 34Xx to 40Xx - Disturbance on PV Array
79
Error Numbers 60Xx to 90Xx - Disturbance on the Sunny Central
81
Instantaneous Values
85
Sunny Central
85
Power Limitation
85
Error Channels
86
Measured Values
86
Internal Device Values
87
Internal Meters
87
Service-Relevant Display Values
87
Sunny Central String-Monitor Controller
88
Instantaneous Values
88
Internal Device Values
88
Status Values
88
Sunny String-Monitor
89
Instantaneous Values
89
Internal Device Values
89
Status Values
89
Parameters
90
Sunny Central
90
Power Limitation
90
Grid Monitoring/Grid Limits
98
Grid Support
100
Insulation Monitoring
101
Internal Device Values
101
Sunny Central String-Monitor Controller
103
Sunny String-Monitor
105
Contact
107
Advertisement
SMA Sunny Central 500CP-JP Maintenance Manual (68 pages)
Brand:
SMA
| Category:
Inverter
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Information on this Document
6
Validity
6
Target Group
6
Additional Information
6
Levels of Warning Messages
6
Symbols in the Document
7
Typographies
7
Designations in the Document
7
2 Safety
8
Intended Use
8
Safety Information
9
Personal Protective Equipment
12
3 Product Overview
13
Design of the Inverter
13
Devices of the Inverter
13
Operating and Display Elements
14
Function of the Switches
14
Key Switch
14
AC Disconnection Unit
15
DC Switchgear
15
Touch Display
16
Design
16
Explanation of Symbols
16
Leds of the SC-COM
20
Leds on the Enclosure
20
Leds on the Network Port
21
Leds on the Optical Fiber Terminals
22
User Interface
23
Design of the User Interface
23
Tree View and Device View
23
Status Symbols
24
Symbols on the Product
24
4 Disconnecting and Reconnecting
25
Safety When Disconnecting and Reconnecting Voltage Sources
25
Disconnecting the Inverter
25
Switching off the Inverter
25
Disconnecting the DC Side
25
Disconnecting the AC Side
26
Disconnecting the Supply Voltage at the Inverter from Voltage Sources
26
Reconnecting the Inverter
27
Reconnecting the Supply Voltage at the Inverter
27
Reconnecting the AC Side
27
Reconnecting the DC Side
28
Restarting the Inverter
28
5 Troubleshooting
29
Safety During Troubleshooting
29
Reading off Disturbance Messages
29
Reading off Error Messages Via Touch Display
29
Reading off Disturbance Messages Via the User Interface
30
Displaying the Event Report
30
Enabling Automatic Read-Out of Events
30
Displaying and Downloading the Event Report
30
Acknowledging Disturbance Messages
30
Acknowledging Disturbance Messages Via the Key Switch
30
Acknowledging Disturbance Messages Via the User Interface
31
Remedial Action in Case of Disturbances
31
Inverter Behavior in Case of Disturbances
31
Content and Structure of the Error Tables
33
Error Numbers 01Xx to 13Xx - Disturbance on the Utility Grid
33
Error Numbers 34Xx to 40Xx - Disturbance on the PV Array
34
Error Numbers 6Xxx to 9Xxx - Disturbance on the Inverter
36
Displaying Disturbance Messages for Active Power Limitation
39
Displaying Disturbance Messages for the Reactive Power Setpoint
40
6 Maintenance
41
Safety During Maintenance
41
Maintenance Schedule and Consumables
42
Notes on Maintenance Work
42
Maintenance Work Every 24 Months
42
Repair Schedule and Spare Parts
43
Information on Repair Work
43
Demand-Based Annual Repairs
43
Repairs Every 10 Years
44
Repairs Every 12 Years
44
Maintenance Work
45
Maintenance Work with Supply Voltage Present
45
Checking the DC Switchgear
45
Checking the AC Disconnection Unit
46
Checking the Fans
47
Checking the Heating Elements and Hygrostat
48
Checking the Function of the UPS
49
Maintenance Work in Disconnected State
50
Performing the Visual Inspection
50
Analyzing the Temperature Indicators
51
Cleaning the Ventilation Plate
52
Cleaning the Air Duct, Ventilation Grids and Air Intake
53
Cleaning the Interior
55
Checking the Seals
55
Checking the Latches, Door Stops and Hinges
56
Checking the Inverter Surface
57
Checking the Fuses/Disconnection Blades
58
Checking the Bolted Connections of the Power Cabling
58
Checking the Surge Arresters
59
Checking the Labels
60
Repair Work
60
Reading off the Replacement Interval Meter
60
7 Periodic Actions
61
Mounting and Disassembly Work
61
Disassembling and Mounting the Panels
61
Disassembling and Mounting the Protective Covers
62
Disassembling and Mounting the Ventilation Grids
63
Entering the Password Via the Touch Display
64
Parameter Overview
64
Accessing the Parameter Overview
64
Saving Parameter Changes
65
User Interface
65
Logging into the User Interface
65
Logging out of the User Interface
65
8 Appendix
66
Installation Information
66
Torques
66
Type Label
66
9 Contact
67
SMA Sunny Central 500CP-JP Installation Manual (78 pages)
Brand:
SMA
| Category:
Inverter
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Information on this Document
6
Validity
6
Target Group
6
Additional Information
6
Levels of Warning Messages
6
Symbols in the Document
7
Typographies
7
Designations in the Document
7
2 Safety
8
Intended Use
8
Safety Information
9
Personal Protective Equipment
12
3 Product Overview
13
Design of the Inverter
13
Devices of the Inverter
13
Symbols on the Product
14
4 Transport and Mounting
15
Safety During Transport and Mounting
15
Requirements for Transport and Mounting
15
Requirements and Ambient Conditions
15
Center of Gravity Marker on the Inverter
16
Preparation for Mounting
16
Drilling Mounting Holes in the Foundation
16
Preparation for Mounting on a Base
16
Transporting the Inverter
17
Transporting the Inverter Using a Pallet Truck
17
Transporting the Inverter Using a Forklift or a Crane Fork
17
Transporting the Inverter Using a Crane
18
Mounting of the Inverter
20
Mounting the Inverter on a Foundation
20
Mounting the Inverter on a Base
20
5 Installation
21
Safety During Installation
21
Preparing the Installation
22
Mounting the Silencing Baffle
22
Replacing the Desiccant Bag in the Inverter
23
Mounting the Ventilation Plate
23
Installing the Grounding
23
Installing the DC Connection
24
Connecting the DC Cable to the Busbar
24
Connecting the DC Cables to the Connection Brackets
26
Installing the AC Connection
27
Cables for Communication, Control, Supply Voltage and Monitoring
29
Connecting Optical Fibers with Subscriber Connector
29
Connecting Optical Fibers Via Optical Fiber Pigtail
31
Connecting the Network Cables
32
Connecting Cables for Analog Setpoints
33
Connecting the Cable for the External Fast Stop
33
Connecting the Cable for Remote Shutdown
34
Connecting the Cable for the Status Report of the Insulation Monitoring
34
Connecting the Cable for the Supply Voltage
34
Connecting the Cable for the Status Report of the AC Contactor Monitoring
35
Connecting the Data Cable of the Sunny String-Monitor
35
Connecting the Transformer Protection
36
6 Disconnecting and Reconnecting
37
Safety When Disconnecting and Reconnecting Voltage Sources
37
Disconnecting the Inverter
37
Switching off the Inverter
37
Disconnecting the DC Side
37
Disconnecting the AC Side
38
Disconnecting the Supply Voltage at the Inverter from Voltage Sources
38
Reconnecting the Inverter
39
Reconnecting the Supply Voltage at the Inverter
39
Reconnecting the AC Side
39
Reconnecting the DC Side
40
Restarting the Inverter
40
7 Periodic Actions
41
Insert the Cable into the Inverter
41
Mounting and Disassembly Work
41
Disassembling and Mounting the Panels
41
Disassembling and Mounting the Protective Covers
42
Disassembling and Mounting the Ventilation Grids
43
Bolted Connections
45
Preparing the Grounding and DC Cables for Connection
45
Preparing the AC Connection
49
Clamp Connections
50
Connecting the Cable to the Spring-Cage Terminals
50
Connecting the Cable Shield Using a Shield Clamping Saddle
51
8 Technical Data
53
Sunny Central 500CP-JP
53
Sunny Central 630CP-JP
55
Sunny Central 800CP-JP
57
Sunny Central 1000CP-JP
59
9 Appendix
62
Information for Installation
62
Requirements for the Mounting Location
62
Requirements for the Support Surface
63
Requirements for the Foundation and Cable Routing
63
Requirements for Cable Routing between MV Transformer and Inverter
64
Dimensions of the Inverter
66
Minimum Clearances
68
Minimum Clearances for Outdoor Installation
68
Minimum Clearances in Electrical Equipment Rooms
71
Grounding Concept
72
Storage
73
Installation Information
73
Torques
73
Reduction of DC Input Currents for DC Fuses
74
Type Label
74
Advertisement
SMA Sunny Central 500CP-JP Installation Manual (28 pages)
Retrofitting of the Option "Noise Reduction"
Brand:
SMA
| Category:
Inverter
| Size: 0 MB
Table of Contents
Table of Contents
3
1 Information on this Document
4
Validity
4
Target Group
4
Levels of Warning Messages
4
Symbols in the Document
5
2 Safety
6
Intended Use
6
Safety Information
7
Personal Protective Equipment
9
3 Product Overview
10
Design of the Inverter
10
Type Label
10
4 Scope of Delivery
11
5 Preparation for Mounting
13
Additionally Required Mounting Material
13
Disconnecting the Inverter
13
6 Mounting
14
Safety During Mounting
14
Disassembling the Kick Plates
14
Removing the Existing Ventilation Plate
15
Disassembling the Rear Panel
15
Mounting the New Rear Panel
17
Mounting the Kick Plate for the Sound Absorber
18
Mounting the Ventilation Plate
18
Mounting the Kick Plate
19
Mounting the Silencing Baffle
19
7 Switching the Inverter on
22
8 Dimensions and Minimum Clearances
23
Dimensions of the Inverter
23
Minimum Clearances for Outdoor Installation
23
9 Technical Data
26
10 Contact
27
Advertisement
Related Products
SMA SUNNY CENTRAL 500CP XT
SMA SUNNY CENTRAL 500CP-US/CA
SMA SUNNY CENTRAL 500CP-US/CA 600V
SMA SC 500CP-US-10 600V
SMA SC 500CP-US-10
SMA SC 500CP-10-XT
SMA SUNNY CENTRAL 500HE-US
SMA STP 5000TL-20
SMA MEDIUM VOLTAGE POWER STATION 500SC-JP
SMA SUNNY BOY 5000TL-21
SMA Categories
Inverter
Paint Sprayer
Control Unit
Measuring Instruments
Controller
More SMA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL