Stopping - SMA Sunny Island 2012 Technical Description

Stand-alone grid inverter
Table of Contents

Advertisement

SMA Solar Technology AG
7.
Press and hold the pushbutton on the Sunny Remote Control 1.
8.
The Sunny Remote Control 1 emits a tone.
9.
The Sunny Island starts.
10. Let go of the pushbutton.
The Sunny Island is in operation.
Starting the Sunny Island automatically
Even if the "250.01 AutoStr" parameter is set, the Sunny Island must be manually started
for inverter operation after each DC start once, each time the DC circuit breaker is started.
If there is an error message
If the device displays an error message, this error must be fixed before the device can be
put into operation. Use the information in section 18 "Troubleshooting/Problem Solving"
(Page 184).

10.1.2 Stopping

Stopping the system with the Sunny Island
Set the Sunny Island to standby.
Proceed as follows:
1.
Press and hold the start / stop button on the Sunny Island until the inverter LED glows orange
continuously.
During the stop procedure the LED goes from green to orange.
2.
Let go of the start / stop button
The Sunny Island has stopped.
The device is now in standby mode.
Technical Description
Operating the Sunny Island
SI2012_2224-TEN082311
85

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunny island 2224

Table of Contents