Ohmmeter
1
Continuity
3
2
Continuity
Ohmmeter
1
No Continuity
3
2
Ohmmeter
4
1
Ohmmeter
3
Continuity
COOLING (5S–FE)
COOLING FAN RELAY
INSPECTION
1.
(a)
No.1 Cooling
(b)
Fan Relay
S05390
(c)
Ohmmeter
If there is no continuity, replace the relay.
4
If there is no continuity, replace the relay.
B02801
(d)
If there is continuity, replace the relay.
Battery
(e)
4
(f)
B02802
2.
No.2 Cooling
(a)
Fan Relay
(b)
S05387
(c)
Continuity
Ohmmeter
2
If there is no continuity, replace the relay.
5
If there is no continuity, replace the relay.
No Continuity
S04972
If there is continuity, replace the relay.
–
COOLING FAN RELAY
INSPECT NO.1 COOLING FAN RELAY
Remove the relay box cover.
Remove the No.1 cooling fan relay. (Marking: FAN NO.1)
Inspect the No.1 cooling fan relay continuity.
(1)
Using an ohmmeter, check that there is continuity
between terminals 1 and 2.
(2)
Check that there is continuity between terminals 3
and 4.
Inspect the No.1 cooling fan relay operation.
(1)
Apply battery positive voltage across terminals 1
and 2.
(2)
Using an ohmmeter, check that there is no continu-
ity between terminals 3 and 4.
Reinstall the No.1 cooling fan relay
Reinstall the relay box cover.
INSPECT NO.2 COOLING FAN RELAY
Remove the relay box cover.
Remove the No.2 cooling fan relay. (Marking: FAN NO.2)
Inspect the No.2 cooling fan relay continuity.
(1)
Using an ohmmeter, check that there is continuity
between terminals 1 and 2.
(2)
Check that there is continuity between terminals 3
and 4.
(3)
Check that there is no continuity between terminals
3 and 5.