The data points included in the daily log and the corresponding log action are as shown in
the table below. Data points required by the API Chapter 21 standard are marked with an
asterisk (*). For information on a particular data point, consult Daniel MeterLink online
help (see the help topic for any data point in Daniel MeterLink. Click Help > Gas 3410
Series Registers Reference, select the Index tab, start typing the data point name until
the desired point is highlighted, and then click the Display button.)
Table 6-1: Daily log content
Data point
PosVolFlow*
NegVolFlow*
PosVolBase
NegVolBase
FlowTemperature*
FlowPressure*
AbsFlowPressure*
AccumFlowTime*
AvgSndVel*
PrevDayMacro1
PrevDayMacro2*:
84
Content
bit 30-31
(unused)
bit 29
DI1
bits 26-28
(unused)
bit 25
IsAcqMode
bit 24
IsAcqModuleError
bit 23
DidPowerFail
bit 22
DidCnfgChksumChg
bit 21
IsElecTempOutOfRange
bit 20
IsElecVoltOutOfRange
bit 19
IsGCAlarmPresent
bit 18
IsGCCommErr
bit 17
IsColocMeterCommErr
bit 16
IsXdcrFiringSyncError
bits 5-15
(unused)
bit 4
IsEstimatedFlowVelocityInUse
bit 3
IsEnergyRateInvalid
bit 2
IsMassRateInvalid
bit 1
IsQBaseInvalid
bit 0
IsQFlowInvalid
Operations manual
DAN-20057316
Log action
Totalize and
Snapshot
Totalize and
Snapshot
Totalize and
Snapshot
Totalize and
Snapshot
Flow-Gated
Flow-Gated
Flow-Gated
Totalize
Flow-Gated
Macro
Paths A-H,
8-path meters
Macro
Operations manual