Emerson Daniel 3410 Series Operation Manual page 78

Gas ultrasonic flowmeters
Hide thumbs Also See for Daniel 3410 Series:
Table of Contents

Advertisement

Configurations
January 2019
Mode
Select Scroll items 1-10 or Uncorrected volume only. The default value is Scroll items 1-10.
Scroll items 1-10 mode, allows selection of up to ten data points to be displayed on the
local display. In Uncorrected volume only mode, the display will only alternate between
the forward and reverse uncorrected volume in units of cubic meters in compliance with
OIML R-137-1 and the European MID directive. Depending on the size of the meter, the
value displayed in the Uncorrected volume only mode will be X 10 cubic meters or X 100
cubic meters as indicated on the display in the bottom line.
Display items and display units
Display units - Meter volume units displayed are either U.S. Customary or Metric. The Meter
volume units displayed reflect the meter's units selected on the File > Program Settings
dialog (e.g. U.S. Customary or Metric units). Configure the Meter volume units for U.S.
Customary selections:
Cubic feet,
Thousand cubic feet Or
Metric unit selections are:
Cubic meters
Thousand cubic meters
Configure the Flow rate time units:
Second
Hour
Day
Display units preceded by a plus or minus sign indicate forward and reverse flow
direction, as shown in the table below.
Table 5-16: Local display labels, descriptions and valid units
Local display labels, descriptions and valid units
QFLOW - Uncorrected volume flow rate
TDYVL - Current day's forward uncorrected volume
78
ACF - Actual Cubic Feet
ACM - Actual Cubic Meters
MACF - Thousand Actual Cubic Feet
MACM - Thousand Actual Cubic Meters
+ACF - Actual Cubic Feet
+ACM - Actual Cubic Meters
+MACF - Thousand Actual Cubic Feet
+MACM - Thousand Actual Cubic Meters
Operations manual
DAN-20057316
Operations manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Daniel 3418

Table of Contents