DAN-20057316
Table 5-7: Flow-condition pressure and temperature data source
Input Type
(EnablePressureInput
or
EnableTemperaturein
put)
Disabled
Live
(1)
Live input can be invalid due to (a) one or more live values is/are at or outside the alarm limits, or
(b) the input is being calibrated.
The flow-condition absolute flow pressure is calculated as shown in
absolute
Equation 5-6: Flow-condition absolute pressure
where
P
abs,f
P
f
InputPressureUnit=TRUE) (FlowPressure)
P
Atmosphere
5.7.2
Configure the temperature parameters for the meter
Live temperature - if Live Analog was selected for Temperature for meter corrections on
the Daniel MeterLink Startup Page, enter the scaling for the transmitter connected to
the analog input. Minimum input is the zero scale temperature of the transmitter (i.e. 1
Volt or 4mA). Maximum input is the full scale temperature of the transmitter (i.e. 5
Volts or 20 mA).
Model 3418 GUSM
Data Validity
(PressureValidity or
TemperatureValidity)
N/A
Valid
(1)
Invalid
Valid
Invalid
pressure.
P
= P
+P Atmospℎere
abs, f
f
P
= P
InputPressureUnit = TRUE Absolute
abs, f
f
= flow-condition absolute pressure (MPaa) (AbsFlowPressure)
= flow-condition pressure (MPa if InputPressureUnit=FALSE, MPaa if
= (specified) atmospheric pressure (MPaa) (AtmosphericPress)
Data Source Upon
Alarm
(FloePOrtSrcUponA
larm)
N/A
N/A
Last good value
Fixed
N/A
Last good value
InputPressureUnit = FALSE Gage
Configurations
January 2019
"In-Use" Data Source
(FlowPressure or
FlowTemperature)
"In-Use" value unchanged
Average of live values
(LiveFlowPressure or
FlowTemperature)
"In-Use" value unchanged
Fixed data point
(SpecFlowPressure or
SpecFlowTemperature)
Fixed data point
(SpecFlowPressure or
SpecFlowTemperature)
"In-Use" value changed
Fixed data point
(SpecFlowPressure or
SpecFlowTemperature)