Operations manual
DAN-20057316
Frequency or Digital Outputs (FODO2, FODO3, FODO4, FODO5) source options ~
Group 2
•
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
•
Frequency output 1A is the A Phase of Frequency output 1 content (Uncorrected
volume flow rate, Corrected volume flow rate, Average flow velocity, Average speed of
sound, Energy flow rate, Mass flow rate)
•
Frequency output 1B is the B Phase of Frequency output 1
•
Frequency output 2A is the A Phase of Frequency output 2 content (Uncorrected
volume flow rate, Corrected volume flow rate, Average flow velocity, Average speed of
sound, Energy flow rate, Mass flow rate)
•
Frequency output 2B is the B Phase of Frequency output 2 content
•
Digital output 1A is based on Digital output1A content (Frequency Output 1 Validity,
Flow Direction, Process Validity)
•
Digital output 1B is based on Digital output1B content (Frequency Output 1 Validity,
Flow Direction, Process Validity)
•
Digital output 2A is based on Digital output 2A content (Frequency Output 2 Validity,
Flow Direction, Process Validity)
•
Digital output 2B is based on Digital output 2B content (Frequency Output 2 Validity,
Flow Direction, Process Validity)
Mode options
•
Open Collector (requires external excitation supply voltage and pull-up resistor)
•
TTL (internally powered by the meter 0-5 VDC signal)
Channel B Phase options:
•
Lag forward, Lead reverse (Phase B lags Phase A while reporting forward flow, leads
Phase A while reporting reverse flow)
•
Lead forward, Lag reverse (Phase B leads Phase A while reporting forward flow, lags
Phase A while reporting reverse flow)
Phase A and Phase B output (based on flow direction)
•
Reverse flow - output only reports flow in the reverse direction. For frequency outputs,
Phase B of the output is 90 degrees out of phase with Phase A.
•
Forward flow - output only reports flow in the forward direction. For frequency outputs,
Phase B of the output is 90 degrees out of phase with Phase A.
•
Absolute - output reports flow in both directions. For frequency outputs, Phase B of the
output is 90 degrees out of phase with Phase A.
•
Bidirectional - output reports flow on Phase A only in the forward direction and on
Phase B only in the reverse direction.
Maximum frequency for the frequency outputs
•
1000Hz
•
5000Hz
Model 3418 GUSM
Configurations
January 2019
57