9. Enter a Comment to associate with the SOS calculation. The comment is included in
10. Click Save to save the Meter Name if connected to a meter, Company Name as set
11. Click Open to select a saved gas composition file to bring into the SOS Calculator.
12. Click Calculate to compute the calculated values.
13. Click Print to print the Meter name if connected to a meter, Company name as set
14. If the SOS Calculator was launched from Maintenance Logs and Reports, click Finish
15. If the SOS Calculator was launched from the Tools > SOS Calculator menu, click
7.1.4
Outputs test
The Outputs Test dialog box allows you to monitor the live values of all the frequency,
current and digital outputs. Additionally the outputs can be set into a Test mode to force
the outputs to a specific user defined value. This dialog box is only available while
connected to a meter.
Refer to
Test Mode.
7.1.5
Transducer swap-out
The transducer swap-out utility allows you to update parameters such as path lengths,
delay times, and delta times for chord. This is necessary anytime transducers, mounts,
holders, or stalks have to be replaced for a chord.
Refer to the Daniel 3410 Series Gas Ultrasonic Flow Meters Maintenance and Troubleshooting
Manual (P/N DAN-XXXXXXXX) for detailed instructions for replacing the transducers,
mounts and stalks and setting the parameters for the pairs of transducers you replaced.
Model 3418 GUSM
saved gas composition files and print outs.
under File > Program Settings, Date and Time based on the PC clock, Comment,
Gas composition inputs, Pressure/temperature inputs, and Calculated values to a
comma- separated values (.csv) file.
Only the Gas composition inputs, Pressure/temperature inputs, and Comment are
imported from a saved file.
Note
The SOS Calculator can open the comma-separated value files exported from
MON20/20 or MON2000 Software for Gas Chromatographs Calculation Results
screen. If you have customized any of the component names in the gas
chromatograph you will need to modify the SOS Calculator's map file. Daniel
MeterLink lists any component names that cannot be processed.
under Program Settings, Date and Time based on the PC clock, Comment, Gas
composition inputs, Pressure/temperature inputs, and Calculated values.
to accept the calculation and finish creating the Maintenance log. Click Cancel to
skip the computed SOS and continue making the Maintenance log.
Close to return to the Main window of Daniel MeterLink
Outputs test mode
in this manual for additional information about the Outputs
Commands