Gas ultrasonic flowmeters
Hide thumbs Also See for Daniel 3410 Series:
Table of Contents

Advertisement

Operations manual
DAN-20057316
Select baseline flow direction - forward or reverse
Select baseline data source
Configure the local display
Configure the parameters for the local display.
Use the drop-down arrow in the Display Items list box and select or modify the parameters
that will be displayed; the Display items, the Display units and the Scroll delay.
Important
When connected to a meter with the local display option, reverse flow direction is
indicated with a minus sign (negative) before the value(s) shown on the local display.
Figure 5-13: Field Setup Wizard - Local Display
Model 3418 GUSM
1-minute averages from the meter - the preferred option when setting the baseline
for a new meter. The meter must be under typical flowing conditions when the
baseline is set.
Maintenance log - if the meter has already been installed in the field for a period of
time and a Daniel MeterLink maintenance log is available from the initial startup
that was taken during normal flowing conditions.
Manual entry - manually enter data for each of the parameters. This could be used
to modify a single parameter for a baseline already set or it could be to enter data
from a historical record from when the meter was first put into service.