Table 5-15: GC-read gas property invalid conditions
Indication Data Point
IsGCDataErr
GC alarm handling
The following data points are included in the meter's alarm log (See
audit): AreGasPropertiesInvalidGC, IsGCAlarmPresent, IsGCCommErr, GCCommStatus,
and IsGCDataErr.
5.8.2
Configure AGA8 parameters
Configure the properties necessary for the AGA8 calculations.
How the AGA8 calculations to be performed:
Internally by the meter - calculates the flow mass density, the flow compressibility and
the base compressibility.
Externally - calculations are done externally. The calculated values must then be written
to the meter using Daniel MeterLink
AGA8 method
Gross Method 1
Gross Method 2
Detail - enter the amount of each of the 21 gas components as a percentage.
GERG-2008
Gas composition
Fixed - use the fixed gas composition stored in the meter for all calculations.
Live GC - use a gas composition collected by the meter from a gas chromatograph for
all calculations. This option is only available with a GC key or is enabled with the
Continuous Flow Analysis key.
Configure the Gas properties for the gas chromatograph
Base temperature
Base pressure
Gas composition to use on GC alarm
Specific gravity
Specific gravity reference temperature
Model 3418 GUSM
Condition
The total unnormalized gas composition mole percentage is not within
[85%, 115%].
An individual gas composition mole percentage is not within [0%, 100%].
The specific gravity is not within [0.2, 0.8].
The heating value is greater than 50 kJ/dm
or a flow computer.
Configurations
(continued)
3
.
Event log: alarm/