Model 3418 GUSM
Note
®
For Windows
7, you cannot use the Communications cable between two
computers at this time and must use the Daniel Direct Connection driver.
Baud Rate: Select the serial port baud rate from the drop-down list for
which the meter hardware is configured. The default Baud Rates is 19200.
Check Box labeled Route IP packets to connection to configure MeterLink
to automatically connect to both Transmitter heads of Dual-
Configuration meters when data sharing is enabled. This requires
Ethernet connection between the two heads.
b) Modem connection- set the following properties to connect to the meter via
a modem.
Protocol and Comms Address: Use the Protocol and Comms Address
parameters in
Step
Modem: Select the modem to use from the drop-down list. Only modems
installed in Windows
blank, then no modems have been installed for Windows
Note
Do not select Daniel Direct Connection or Communications cable
between two computers for the modem. This is a NULL modem driver for
direct connection to Daniel Ultrasonic meters only. It will not work for the
Modem connection.
Daniel MeterLink uses the Microsoft
modem and direct serial connections to a meter. Click Modem Properties
to bring up the Dial-up networking entry Daniel MeterLink
for this meter. Most of the information required is setup correctly by
Daniel MeterLink
Baud Rate: Select the desired Baud Rate from the drop-down list.
Telephone #: Enter the telephone number for the modem to which the
meter is connected. Include digits to obtain to an outside line, if
necessary. Inserting commas between the digits pauses the dialing rate.
Each comma is approximately equal to two seconds.
Modem Properties: configures the properties associated with the
modem.
Daniel MeterLink uses the Microsoft
modem and direct serial connections to a meter. Click Modem Properties
to bring up the Dial-up networking entry Daniel MeterLink has created for
this meter. Most of the information required is setup correctly by Daniel
MeterLink. Click OK to accept the changes or click Cancel to discard any
changes and return to the Meter Directory dialog box.
c) Ethernet connection - Set the following properties to configure the Daniel
ultrasonic meter hardware for Ethernet connectivity.
3a.
®
show in the drop-down list. If the drop-down list is
®
Dial-up Networking for making
.
®
Dial-up Networking for making
Communications
January 2019
®
.