MIMAKI TS55-1800 Operation Manual page 114

Color inkjet printer
Table of Contents

Advertisement

Chapter5 Troubleshooting
Display
ERROR 651
REPLACE NCU
ERROR 652
NCU NZK CHK (HW)
ERROR 653
NCU NZK CHK (MARK)
ERROR 654
NCU CENTER POS
ERROR 655
NCU FLUSH POS
ERROR 656
NCU SN ADJST
ERROR 657
REPLACE NCU INK PAD
ERROR 658
NCU SENSOR LV LOW
ERROR 65b
NCU Sens Adj Err H
ERROR 65c
NCU Sens Adj Err L
ERROR 702
THERMISTOR CONNECT
ERROR 710
HEATER TEMP ERROR
ERROR 901
INVAILD OPERATION
ERROR 902
DATA REMAIN
ERROR 90d
NO HEAD SELECT
ERROR 90f
PRINT AREA SHORT
ERROR 91a
ADJUST HEAD HEIGHT
ERROR 04
PARAM ROM
ERROR d09
HD MEMORY [1234]
5-14
Cause
The NCU sensor sensitivity is too low to
correctly judge missing lines (due to noz-
zle clogging).
The nozzle check function cannot be
used.
Nozzle clogging and deflection occur fre-
quently,
And the NCU cannot correctly recognize
the ink discharge.
Failure to adjust the discharge position
to the NCU.
Sensor sensitivity adjustment has failed.
Ink absorbent of NCU is full.
The NCU sensor sensitivity is falling.
Cannot adjust the sensor sensitivity.
A thermistor connection error has
occurred.
Heater temperature abnormality was
detected.
If the temperature abnormality cannot be
resolved after this error occurred, forci-
bly turn off the machine power.
Due to a certain error, the function can-
not be performed.
There is remaining print data.
An error occurred in the mounted heads.
Media width or media length required for
printing is insufficient.
There is a difference between the head
height set value stored in the machine
and the current head height.
An error occurred in the MAIN PCB
FROM.
An error was detected in the built-in
head memory.
Measures
• NCU replacement is required.
Contact your local distributor, our sales
office, or service center.
• Check the nozzle condition. If there is a
great amount of missing lines (due to nozzle
clogging) or deflection, clean the affected
nozzles.
• Check the nozzle condition. If there is a
great amount of missing lines (due to nozzle
clogging) or deflection, clean and restore the
affected nozzles.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
• Contact your local distributor, our sales
office, or service center.
• Replacement of the NCU is recommended.
Contact your local distributor, our sales
office, or service center.
• Turn off the power on the machine and turn it
on after a while.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
• Return to the local mode screen and check
the error situation and take appropriate
action.
• Clear the data.
(
P.2-13)
• Turn off the power on the machine and turn it
on after a while.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
• Change the media to the one with enough
width or length.
• When the media width narrows because the
origin moved, slide the origin to the right to
widen the effective media width.
• Set the head height.
(
P.2-4)
• Turn off the power on the machine and turn it
on after a while.
If displaying again, contact your local distrib-
utor, our sales office, or service center.