Display
ERROR 171
NEW HEAD CONNECT
ERROR 18a
Main PCB V_CORE
ERROR 18c
Main PCB V12
ERROR 18e
FLS NOT COMP
ERROR 18f
OFFSET START
ERROR 18f
OFFSET END
ERROR 1d9
Main PCB V48-1
ERROR b1b
BaseIO PCB Vpow-s
ERROR b1c
BaseIO PCB V24
ERROR b1d
BaseIO PCB V24-A
ERROR b21
SLIDER1 PCB V3R3
ERROR b22
SLIDER1 PCB V2R5
ERROR b23
SLIDER1 PCB V1R8
ERROR b24
SLIDER1 PCB V1R2
ERROR b21
SLIDER2 PCB V3R3
ERROR b22
SLIDER2 PCB V2R5
ERROR b23
SLIDER2 PCB V1R8
ERROR b24
SLIDER2 PCB V1R2
ERROR 1e6
PRAM Size Shortage
ERROR 201
COMMAND ERROR
ERROR 202
PARAMETER ERROR
ERROR 206
PRINTING MODE
ERROR 304
USB INIT ERR
ERROR 305
USB TIME OUT
ERROR 307
MCFD File IF Error
ERROR 401
MOTOR X
5-12
Cause
An error occurred in the power supply
system of the main PCB.
An error occurred in the power supply of
the main PCB.
Detected an error in the waveform for
the printing.
An error occurred in the power supply of
the main PCB.
An error occurred in the power supply of
the BaseIO PCB.
An error occurred in the power supply of
the slider M PCB.
Memory size is insufficient.
Data other than print data was received.
Or, an error occurred in the transmitted
print data.
An error occurred in the transmitted print
data.
The machine received print data with
unprintable conditions.
An error occurred in the USB communi-
cation.
An error occurred while accessing the
printing condition data.
An excessive load was applied to the X
motor.
Measures
• Turn off the power on the machine and turn it
on after a while.
If displaying again, contact your local distrib-
utor, our sales office, or service center.
• Securely connect the interface cable.
Use an interface cable conforming to the
standard.
• Check the print data output condition of the
RIP software.
• Check the profile.
• If displaying again, contact your local distrib-
utor, our sales office, or service center.
• Turn off the power on the machine and turn it
on after a while.
If displaying again, contact your local distrib-
utor, our sales office, or service center.