NE 53 history
December 2001, version 3.x
Modification type
Expansion
Adjustment
Feature
June 2003, version 4.x
Modification type
Expansion
Adjustment
Feature
234
Change
•
Added support for the configurable I/O option board
•
Software version information available via the display or
Modbus
•
Configurable density cutoff
•
Additional HART variables can be assigned to QV
•
The display start/stop totalizers function can be enabled or
disabled
•
Petroleum measurement application improvements
•
Live zero available as display variable
•
Increased options for fault output settings
•
New cryogenic application temperature algorithms
•
Improved Frequency Output stability and unit conversions
•
Improved the handling of volume flow rate when two-phase
flow is detected
•
Improved handling of density values and calibrations during
fault conditions
•
Display configuration, screen flow and optical switch changes
•
HART communication and burst mode improvements
•
Petroleum measurement application added
•
Custody transfer option added to the configurable I/O option
board
•
HART polling for external pressure/temperature added
Change
•
Added support for the Model 1500 transmitter
•
Additional variables displayed by the Model 1700 transmitter
•
Improved the handling of certain alarm conditions
•
Clarified the behavior of certain Modbus calibration coils
•
Clarified the interaction between certain density measure-
ment units and density cutoff values
•
Improved the handling of the mA source setting via the dis-
play
•
Improvements to pressure and temperature polling
•
HART Tri-Loop and other communication improvements
•
Clarified the value returned by Modbus scaled integer regis-
ters during a fault condition
Discrete values now available through Modbus
Micro Motion Model 1700 Transmitters with Analog Outputs