Product Data Sheet PS-00291, Rev. B May 2007 ® Micro Motion Series 3000 Transmitters and Discrete Controllers ® Micro Motion Series 3000 electronics combine transmitter functions and PLC capabilities in one instrument. Series 3000 models feature MVD™ technology, providing high-speed DSP capabilities and a broad range of specialty applications.
Page 2
Micro Motion transmitters and controllers Micro Motion transmitters and controllers fit a wide variety of application needs. The table below can help determine which Micro Motion products are right for your process. For more detailed product information, consult the appropriate Product Data Sheet or contact your local Micro Motion representative. 1500 1700 2400S...
Series 3000 transmitters and discrete controllers MVD technology. MVD technology makes your Series 3000 transmitters and controllers with MVD Micro Motion meter work smarter. Front-end digital technology. Model 3500 and 3700 transmitters processing dramatically reduces signal noise and deliver process measurement and discrete control gives you faster response time compared to analog based on direct input from a Micro Motion Coriolis devices.
Housings Rack-mount 19-inch (486.2 mm) rack-mount housing meets DIN standard 41494 and IEC 297-3 Front panel is rated IP40 Panel-mount Front panel with bezel is rated NEMA 4X (IP65) Field-mount Compartment with threaded cover contains electronics Terminal compartment contains: • Non-intrinsically safe compartment with input/output and power supply terminals •...
Input signals Non-intrinsically safe input signals One 2-wire Frequency range 0–20,000 Hz 25 μ-sec frequency/pulse input Minimum pulse width Power Sourcing or sinking Voltage 0–0.8 VDC low state 3–30 VDC high state Current Nominal 5 mA pull-up Two discrete Pulse width 0.15 sec minimum momentary inputs Voltage...
Page 7
Output signals continued Fault indication When a fault is detected, outputs go to configured states. User can select upscale, downscale, internal zero, or none. Milliamp outputs conform to NAMUR NE43 (June 1994). Upscale Milliamp 21 to 24 mA, user configurable Frequency 15,000 Hz Downscale...
Environmental specifications EMI effects All Series 3000 devices Meet EMC directive 89/336/EEC per EN 61326 Industrial, and all Series 3000 devices conform to NAMUR NE21 (June 1997). Ambient temperature effect On analog outputs ±0.005% of span per °C Ambient temperature limits Operating –4 to +140 °F –20 to +60 °C...
Hazardous area classifications UL is a U.S.A. approvals agency. CSA is a Canadian approvals agency that provides approvals accepted in both the U.S.A. (C-US) and Canada. ATEX is a European directive. UL and CSA Model 3300 Class I, Div. 2, Groups A, B, C, and D when installed in a suitable enclosure Model 3350 Class I, Div.
Model 3100 accessory Relays module Three relays Solid state, SPST Rated at 24–250 VAC, 40 mA to 5 A; or 0–70 VDC, 5 A Energized by discrete outputs NEMA 4X (IP65) enclosure (optional) UL and CSA approvals Class I, Div. 2, Groups A, B, C, and D ATEX approvals Suitable for installation in Zone 2, when properly installed in a suitable enclosure, complying with ATEX Directive (94/9/EC) for Group II, Category 3G, according to CENELEC standard EN 50021...
Ordering information — Model 3300 Model Product description 3300 Micro Motion Coriolis Discrete Controller; remote rack/panel-mount Code Mounting options DIN rack Panel-mount Code Power supply options 85 to 265 VAC 18 to 30 VDC (recommended for 24 VDC users) Code Communication gateway module No communication gateway module Code...
Page 17
Ordering information — Model 3300 continued Code Language English local display Danish quick reference guide English manual English local display Dutch quick reference guide English manual English local display English quick reference guide English manual French local display French quick reference guide French manual German local display German quick reference guide...
Page 18
Ordering information — Model 3350 Model Product description 3350 Micro Motion Coriolis Discrete Controller; remote field-mount Code Mounting options Field-mount Code Power supply options 85 to 265 VAC 18 to 30 VDC (recommended for 24 VDC users) Code Communication gateway module No communication gateway module Code Additional hardware modules...
Page 19
Ordering information — Model 3350 continued Code Language English local display Danish quick reference guide English manual English local display Dutch quick reference guide English manual English local display English quick reference guide English manual French local display French quick reference guide French manual German local display German quick reference guide...
Page 20
Ordering information — Model 3500 Model Product description 3500 Micro Motion Coriolis multivariable transmitter and discrete controller; remote rack/panel-mount Code Mounting options DIN rack Panel-mount Code Power supply options 85 to 265 VAC 18 to 30 VDC (recommended for 24 VDC users) Code Remote core processor Sensor interface code 5...
Page 21
Ordering information — Model 3500 continued Code Language English local display Danish quick reference guide English manual English local display Dutch quick reference guide English manual English local display English quick reference guide English manual French local display French quick reference guide French manual German local display German quick reference guide...
Page 22
Ordering information — Model 3700 Model Product description 3700 Micro Motion Coriolis multivariable transmitter and discrete controller; remote field-mount Code Mounting options Field-mount Code Power supply options 85 to 265 VAC 18 to 30 VDC (recommended for 24 VDC users) Code Remote core processor Sensor interface code 5...
Page 23
Ordering information — Model 3700 continued Code Language English local display Danish quick reference guide English manual English local display Dutch quick reference guide English manual English local display English quick reference guide English manual French local display French quick reference guide French manual German local display German quick reference guide...
Page 24
Ordering information — Model 3100 high energy relay Model Product description 3100 Micro Motion Coriolis High Energy Relay Code Device (order separately) 3 relays; 24–250 VAC; 5 A 3 relays; 0–70 VDC; 5 A Code Housing No housing NEMA 4X housing for relays only Code Future expansion Reserved for future use...
Page 25
® Micro Motion Series 3000 Transmitters and Discrete Controllers...
Page 26
® Micro Motion Series 3000 Transmitters and Discrete Controllers...
Page 27
® Micro Motion Series 3000 Transmitters and Discrete Controllers...
Page 28
Micro Motion, Inc., Boulder, Colorado. Micro Motion is a registered trade name of Micro Motion, Inc., Boulder, Colorado. The Micro Motion and Emerson logos are trademarks and service marks of Emerson Electric Co. All other trademarks are property of their respective owners.
Need help?
Do you have a question about the Micro Motion Transmitters and Discrete Controllers Series 3000 and is the answer not in the manual?
Questions and answers