Mitsubishi Electric MELSEC iQ-R Series User Manual page 129

Cc-link ie field network waterproof/dustproof remote i/o module (with safety functions)
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

EMC Directive related standards
■Emission requirements
Standard
Test item
EN61131-2: 2007
CISPR16-2-3
Radiated emission
CISPR16-2-1,
CISPR16-1-2
Conducted emission
*1 QP: Quasi-peak value, Mean: Average value
■Immunity requirements
Standard
Test item
EN61131-2: 2007
EN61000-4-2
Electrostatic discharge
immunity
EN61000-4-3
Radiated, radio-
frequency,
electromagnetic field
immunity
EN61000-4-4
Electrical fast transient/
burst immunity
EN61000-4-5
Surge immunity
EN61000-4-6
Immunity to conducted
disturbances, induced by
radio-frequency fields
EN61000-4-8
Power-frequency
magnetic field immunity
EN61000-4-11
Voltage dips and
interruption immunity
*1 The accuracy of an analog-digital converter module may temporarily vary within 10%.
Test details
Radio waves from the product are
measured.
Noise from the product to the power
line is measured.
Test details
Immunity test in which electrostatic
is applied to the cabinet of the
equipment.
Immunity test in which electric fields
are irradiated to the product.
Immunity test in which burst noise is
applied to the power line and signal
line.
Immunity test in which lightning
surge is applied to the power line
and signal line.
Immunity test in which high
frequency noise is applied to the
power line and signal line
Immunity test in which the product
is installed in inductive magnetic
field
Immunity test in which power
supply voltage is momentarily
interrupted
Appendix 5 EMC, Low Voltage, and Machinery Directives
Value specified in standard
• 30 to 230MHz QP: 40dBV/m (measured at 10m distance)
• 230 to 1000MHz QP: 47dBV/m (measured at 10m distance)
• 0.15 to 0.5MHz QP: 79dB, Mean: 66dB
• 0.5 to 30MHz QP: 73dB, Mean: 60dB
Value specified in standard
• 8kV: Air discharge
• 4kV: Contact discharge
80% AM modulation @1kHz
• 80 to 1000MHz: 10V/m
• 1.4 to 2.0GHz: 3V/m
• 2.0 to 2.7GHz: 1V/m
• AC/DC main power, I/O power, AC I/O (unshielded) lines: 2kV
• DC I/O, analog, communication lines: 1kV
• AC power, AC I/O power, AC I/O (unshielded) lines: 2kV CM,
1kV DM
• DC power, DC I/O power lines: 0.5kV CM, 0.5kV DM
*1
• DC I/O, AC I/O (shielded), analog
CM
0.15 to 80MHz,
80% AM modulation @1kHz, 10Vrms
50/60Hz, 30A/m
• Apply at 0%, 0.5 cycles and zero-cross point
• 0%, 250/300 cycles (50/60Hz)
• 40%, 10/12 cycles (50/60Hz)
• 70%, 25/30 cycles (50/60Hz)
*1
*1
, communication lines: 1kV
A
APPX
127

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nz2gfs12a2-14dtNz2gfs12a2-16dte

Table of Contents